m+Medelevator.RU
← Поиск публикаций
Medicina (Kaunas, Lithuania) · 2026

Calculation of Ejection Fraction Using Cardiac Computed Tomography: Clinical Evolution, Reliability, and Technological Challenges-A Narrative Review.

СтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Steffani Simone, Piscione Mariagrazia, Gaudio Dario, Meghnagi Giorgia, Crignola Gianluca Guelfand, Asmundo Luigi, Tagliati Corrado, Laudazi Mario, Chiocchi Marcello

Аннотация

Background: The Ejection Fraction (EF) represents a fundamental pillar for the phenotypic classification and clinical management of cardiovascular diseases. Although trans-thoracic echocardiography (TTE) acts as the first-line examination and cardiac magnetic resonance (CMR) is the reference gold standard, cardiac computed tomography (CCT) has undergone a technological evolution. The advent of wide-detector scanners and artificial intelligence (AI) models has enabled CCT to transition from a purely morphological tool to a modality capable of comprehensive, three-dimensional morpho-functional assessments. Methods: This narrative review evaluates the literature across Scopus, MEDLINE, and Web of Science regarding the calculation of biventricular function and EF using CCT. It provides an updated summary of current clinical applications, technological advancements, and comparative diagnostic reliability against TTE and CMR. Results: The CCT "one-stop-shop" concept allows for the simultaneous acquisition of anatomical data and systolic function metrics (EDV, ESV, SV, EF), optimizing clinical workflows at no additional cost. Being intrinsically three-dimensional, CCT bypasses the geometric assumptions and apical foreshortening artifacts typical of 2D-TTE, demonstrating high volumetric concordance with CMR. Nevertheless, structural limitations persist, primarily regarding ionizing radiation exposure, contrast media toxicity, dependence on heart rhythm stability, and lower temporal resolution compared to CMR. Conclusions: EF determination via CCT has achieved technical maturity and clinical validation. While it does not intend to replace TTE or CMR, it offers synergistic data when integrated with primary anatomical indications. Furthermore, AI integration has been shown to potentially automate this workflow, transforming CCT into an opportunistic screening tool for subclinical cardiac dysfunction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты