MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjdh/ztag025

Медицинская библиотека · European heart journal. Digital health · 2026

Artificial intelligence 12-lead electrocardiography to determine atrial fibrillation risk among UK Biobank participants with predisposing conditions.

Zheng Yi, Siontis Konstantinos C, Attia Zachi I, Shiri Isaac, Roten Laurent, Baj Giovanni, Kazaj Pooya Mohammadi, Lopez-Jimenez Francisco, Gersh Bernard J, Gräni Christoph, Reichlin Tobias, Friedman Paul A, Windecker Stephan, Noseworthy Peter A, Siontis George C M

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Artificial intelligence electrocardiography (AI-ECG) algorithms are emerging tools for identifying individuals at risk of atrial fibrillation (AF). We evaluated the predictive performance of a validated AI-ECG algorithm for incident AF in UK Biobank participants with AF risk factors, irrespective of prevalent cardiovascular disease, and its incremental value when added to clinical predictors.

METHODS AND

RESULTS

The AI-ECG tool was applied to sinus rhythm ECGs from UK-Biobank participants with risk factors for AF but no AF. Model performance was evaluated using time-dependent ROC-AUC and Harrell's C-index. Multivariable Cox regression was used to identify clinical risk factors associated with incident AF and to quantify the contribution of AI-ECG. A total of 21 842 participants (56% male) were included. The median follow-up time was 3.7 years (IQR 0.5-5.4) The ECG-AI tool achieved a ROC-AUC of 0.73 (95% CI 0.68-0.78) at 1 and 0.69 (95% CI 0.66-0.72) at 3 years. A multivariable Cox regression model using clinical parameters achieved a ROC-AUC of 0.71 (95% CI 0.66-0.75) at 1 and 0.71 (95% CI 0.68-0.74) at 3 years. By adding ECG-AI to the clinical Cox regression model, the ROC-AUC increased to 0.75 (95%CI 0.71-0.80) at 1 and 0.74 (95% CI 0.71-0.77) at 3 years. AI-ECG showed a hazard ratio of 1.23 per decile increase (95% CI 1.18-1.27).

CONCLUSION

An AI-ECG algorithm improved the prediction of incident AF when added to a clinical parameter-based model over a median follow-up time of 3.7 years among individuals with comorbidities predisposing to AF who may benefit from targeted screening and preventive strategies.

Для цитирования: Zheng Yi, Siontis Konstantinos C, Attia Zachi I, Shiri Isaac, Roten Laurent, Baj Giovanni, Kazaj Pooya Mohammadi, Lopez-Jimenez Francisco, Gersh Bernard J, Gräni Christoph, Reichlin Tobias, Friedman Paul A, Windecker Stephan, Noseworthy Peter A, Siontis George C M. Artificial intelligence 12-lead electrocardiography to determine atrial fibrillation risk among UK Biobank participants with predisposing conditions.. European heart journal. Digital health. 2026. DOI: 10.1093/ehjdh/ztag025.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.