MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40262-025-01607-z

Медицинская библиотека · Clinical pharmacokinetics · 2025

A Pharmacokinetic Analysis of Intravenous Fluconazole in Adult Patients Undergoing Mechanical Circulatory Support Device Implantation.

Cairns Kelly A, Hernandez-Mitre Maria Patricia, Peel Trisha N, Abbott Iain J, Kaye David M, Marasco Silvana, Daly David, Warner Victoria, Coldham Anna, Pope Jeffrey D, Schneider Hans G, Dooley Michael J, Liu Xin, Roberts Jason A, Udy Andrew A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

There is limited information on the pharmacokinetics and optimal dosing of fluconazole in patients undergoing mechanical circulatory support (MCS) device implantation.

AIM: The aim of this study was to describe fluconazole pharmacokinetics and identify dosing regimens that achieve pharmacokinetic/pharmacodynamic targets in this patient cohort.

METHODS

In this prospective, single-centre study, adults undergoing MCS device implantation received intravenous fluconazole 200 mg or 400 mg, continued once daily for 5 days. Fluconazole concentrations were measured at four peri-operative time points, on return to the intensive care unit, and on days 3 and 5 following implantation. The area under the concentration-time curve from time zero to 24 h (AUC0-24) was estimated, with target exposures defined as AUC0-24/minimum inhibitory concentration (MIC) ≥ 50 for prophylaxis and AUC0-24/MIC ≥ 100 for therapy. Population pharmacokinetic modelling was performed using non-linear mixed-effects methods and for Monte Carlo dosing simulations.

RESULTS

Sixty-five fluconazole concentrations from 10 male patients (median age 51.5 years; IQR 50.0-57.0) were included. A two-compartment model including an additional renal replacement therapy (RRT)-dependent clearance pathway best described the data. Parameter estimates from the final model included a central volume of distribution of 5.75 L, non-RRT clearance of 0.45 L/h, and RRT clearance of 2.22 L/h. Simulations showed that doses of 800 mg or 12 mg/kg would be required for the highest probability of target attainment for Candida fluconazole MICs up to 4 mg/L (AUC0-24/MIC ≥ 50) and 2 mg/L (AUC0-24/MIC ≥ 100).

CONCLUSION

In patients undergoing MCS device implantation, intravenous fluconazole 200 mg administered pre-operatively and continued daily for 5 days is insufficient for Candida spp. with MICs > 1 mg/L (prophylaxis, AUC0-24/MIC ≥ 50) and > 0.5 mg/L (treatment, AUC0-24/MIC ≥ 100).

Для цитирования: Cairns Kelly A, Hernandez-Mitre Maria Patricia, Peel Trisha N, Abbott Iain J, Kaye David M, Marasco Silvana, Daly David, Warner Victoria, Coldham Anna, Pope Jeffrey D, Schneider Hans G, Dooley Michael J, Liu Xin, Roberts Jason A, Udy Andrew A. A Pharmacokinetic Analysis of Intravenous Fluconazole in Adult Patients Undergoing Mechanical Circulatory Support Device Implantation.. Clinical pharmacokinetics. 2025. DOI: 10.1007/s40262-025-01607-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.