DOI 10.1097/ico.0000000000001444
Novel Method to Detect Corneal Lymphatic Vessels In Vivo by Intrastromal Injection of Fluorescein.
Аннотация
PURPOSE: Corneal lymphatic vessels are clinically invisible because of their thin walls and clear lymph fluid. There is no easy and established method for in vivo imaging of corneal lymphatic vessels so far. In this study, we present a novel approach to visualize corneal lymphatic vessels in vivo by injecting intrastromal fluorescein sodium.
METHODS
Six- to eight-week-old female BALB/c mice were used in the mouse model of suture-induced corneal neovascularization. Two weeks after the suture placement, fluorescein sodium was injected intrastromally. The fluorescein, taken up by the presumed lymphatic vessels, was then tracked using a clinically used Spectralis HRA + OCT device. Immunohistochemistry staining with specific lymphatic marker LYVE-1 and pan-endothelial marker CD31 was used to confirm the indirect lymphangiography findings.
RESULTS
By injecting fluorescein intrastromally, both corneal blood and lymphatic vessels were detected. While the lymphatic vessels were visible as bright vessel-like structures using HRA, the blood vessels appeared as dark networks. Fluorescein-labeled lymphatic vessels were colocalized with LYVE-1 in immunohistochemically stained sections of the same specimen.
CONCLUSIONS
Corneal lymphatic vessels can be easily imaged in vivo in the murine model using intrastromal fluorescein injection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.