DOI 10.1111/j.1471-0528.2005.00688.x

Медицинская библиотека · BJOG : an international journal of obstetrics and gynaecology · 2005

Comparison of host response to polypropylene and non-cross-linked porcine small intestine serosal-derived collagen implants in a rat model.

Konstantinovic Maja L, Lagae Pieter, Zheng Fang, Verbeken Eric K, De Ridder Dirk, Deprest Jan A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the host response, architectural integration and tensile strength of polypropylene and porcine small intestine submucosa-derived implants in a rat model.

DESIGN

Experimental study.

SETTING

Center for Surgical Technologies, Faculty of Medicine, Katholieke Universiteit Leuven, Belgium.

SAMPLE: Forty-eight adult male Wistar rats weighing 220-250 g randomised to receive either implant.

METHODS

Full thickness abdominal wall defects were primarily repaired with polypropylene mesh (Marlex) (MX group) or porcine small intestine submucosa (Surgisis) (SIS group). Animals were sacrificed at 7, 14, 30 and 90 days after implantation.

MAIN OUTCOME MEASURES: The presence of herniation, infection and intra-peritoneal adhesions. Change in thickness and tensile strength of implant. Histopathological and immunohistochemical appearances of inflammatory response and collagen deposition.

RESULTS

Implants from the SIS group showed a short term increase in thickness in the first 14 days. Formation of adhesions was significantly more intense in the MX group at 30 days, and more extensive in the SIS group at 90 days. Tensile strength increased over time in both groups but was significantly lower in the SIS group than the MX group at 30 days. Implants in the MX group showed a more pronounced inflammatory response and more pronounced new vessel formation than the SIS group. Collagen formation was initially more fibrous and better organised in the MX group but became greater in the SIS group at 90 days.

CONCLUSIONS

Biologically derived implant material induced a less pronounced inflammatory response and differences in collagen deposition. At 30 days tensile strength was weaker in the biological implant group but was equivalent by 90 days. These differences may have implications for the in vivo performance of the materials.

Для цитирования: Konstantinovic Maja L, Lagae Pieter, Zheng Fang, Verbeken Eric K, De Ridder Dirk, Deprest Jan A. Comparison of host response to polypropylene and non-cross-linked porcine small intestine serosal-derived collagen implants in a rat model.. BJOG : an international journal of obstetrics and gynaecology. 2005. DOI: 10.1111/j.1471-0528.2005.00688.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.