MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.artmed.2016.01.001

Медицинская библиотека · Artificial intelligence in medicine · 2016

Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.

Pérez-López Carlos, Samà Albert, Rodríguez-Martín Daniel, Moreno-Aróstegui Juan Manuel, Cabestany Joan, Bayes Angels, Mestre Berta, Alcaine Sheila, Quispe Paola, Laighin Gearóid Ó, Sweeney Dean, Quinlan Leo R, Counihan Timothy J, Browne Patrick, Annicchiarico Roberta, Costa Alberto, Lewy Hadas, Rodríguez-Molinero Alejandro

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

After several years of treatment, patients with Parkinson's disease (PD) tend to have, as a side effect of the medication, dyskinesias. Close monitoring may benefit patients by enabling doctors to tailor a personalised medication regimen. Moreover, dyskinesia monitoring can help neurologists make more informed decisions in patient's care.

OBJECTIVE

To design and validate an algorithm able to be embedded into a system that PD patients could wear during their activities of daily living with the purpose of registering the occurrence of dyskinesia in real conditions.

MATERIALS AND

METHODS

Data from an accelerometer positioned in the waist are collected at the patient's home and are annotated by experienced clinicians. Data collection is divided into two parts: a main database gathered from 92 patients used to partially train and to evaluate the algorithms based on a leave-one-out approach and, on the other hand, a second database from 10 patients which have been used to also train a part of the detection algorithm.

RESULTS

Results show that, depending on the severity and location of dyskinesia, specificities and sensitivities higher than 90% are achieved using a leave-one-out methodology. Although mild dyskinesias presented on the limbs are detected with 95% specificity and 39% sensitivity, the most important types of dyskinesia (any strong dyskinesia and trunk mild dyskinesia) are assessed with 95% specificity and 93% sensitivity.

CONCLUSION

The presented algorithmic method and wearable device have been successfully validated in monitoring the occurrence of strong dyskinesias and mild trunk dyskinesias during activities of daily living.

Для цитирования: Pérez-López Carlos, Samà Albert, Rodríguez-Martín Daniel, Moreno-Aróstegui Juan Manuel, Cabestany Joan, Bayes Angels, Mestre Berta, Alcaine Sheila, Quispe Paola, Laighin Gearóid Ó, Sweeney Dean, Quinlan Leo R, Counihan Timothy J, Browne Patrick, Annicchiarico Roberta, Costa Alberto, Lewy Hadas, Rodríguez-Molinero Alejandro. Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.. Artificial intelligence in medicine. 2016. DOI: 10.1016/j.artmed.2016.01.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.