Surgeon-Performed Ultrasound in Diagnosing Acute Cholecystitis and Appendicitis.
Аннотация
BACKGROUND
The use of ultrasound (US) outside the radiology department has increased the last decades, but large studies assessing the quality of bedside US are still lacking. This study evaluates surgeon-performed US (SPUS) and radiologist-performed US (RPUS) with respect to biliary disease and appendicitis.
METHODS
Between October 2011 and November 2012, 300 adult patients, with a referral for an abdominal US, were prospectively enrolled in the study and examined by a radiologist as well as a surgeon. The surgeons had undergone a 4-week-long US education. US findings of the surgeon and of the radiologist were compared to final diagnosis, set by an independent external observer going through each patient's chart.
RESULTS
Among 183 patients with suspected biliary disease, 74 had gallstones and 21 had acute cholecystitis. SPUS and RPUS diagnosed gallstones with a sensitivity of 87.1 versus 97.3%. Specificity was 96.0 versus 98.9%, and the accuracy 92.3 versus 98.2%. The sensitivity, specificity and accuracy for acute cholecystitis by SPUS and RPUS were: 60.0 versus 80.0%, 98.6 versus 97.8% and 93.9 versus 95.6%, respectively. Among 58 patients with suspected appendicitis, 15 had the disease. The sensitivity, specificity and accuracy for appendicitis by SPUS and RPUS were: 53.3 versus 73.3%, 89.7 versus 93.3% and 77.3 versus 86.7%, respectively.
CONCLUSION
SPUS is reliable in diagnosing gallstones. Diagnosing cholecystitis and appendicitis with US is more challenging for both surgeons and radiologists.
TRIAL REGISTRATION NUMBER: The study was registered at clinicaltrials.gov. Registration number: NCT02469935.