m+Medelevator.RU
← Поиск публикаций
Oral oncology · 2018

Reader performance in the ultrasonographic evaluation of oropharyngeal carcinoma.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Faraji Farhoud, Padilla Ericka S, Blitz Dana, Wenderoth Meghan B, Blanco Ray G, Kawamoto Satomi, Sheth Sheila, Hamper Ulrike M, Fakhry Carole

Аннотация

OBJECTIVE: To examine reader performance in evaluating oropharyngeal anatomy on ultrasonography.

MATERIALS AND METHODS: Ultrasound images of the oropharynx comprising normal and malignant anatomic variants were organized into slideshows. Slideshows were administered to 6 readers blinded to participant tumor status and with varying experience reading oropharyngeal sonograms. A training slideshow oriented readers to images of the oropharynx with and without malignant lesions. Readers then evaluated images in a test slideshow for tumor presence and marked orthogonal long and short dimensions of the tumor. Results were analyzed for accuracy, sensitivity, specificity, inter-reader agreement, and measurement error relative to prospectively-identified reference measurements.

RESULTS: Eighty-seven percent of base of tongue (BOT) sonograms were identified correctly by a majority of readers. In identifying BOT tumors, median accuracy, sensitivity, specificity, and Fleiss's kappa were 79%, 73%, 85%, and 0.51, respectively. Median measurement error in the long and short axes for BOT tumors was -2.6% (range: -40% to 29%) and -2.6% (range: -56% to 156%), respectively. Eighty-four percent of palatine tonsil sonograms were identified correctly by a majority of readers. In identifying tonsil tumors, median accuracy, sensitivity, specificity, and Fleiss's kappa were 77%, 74%, 78%, and 0.41, respectively. Median measurement error in the long and short axes for tonsil tumors was 3.8% (range: -45% to 32%) and -6.5% (range: -83% to 42%), respectively.

CONCLUSIONS: Overall, US has clinically useful sensitivity for identification of oropharyngeal carcinoma among readers of diverse clinical backgrounds and experience. US may be useful for the evaluation of features such as tumor dimensions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты