Tongue-out versus tongue-in position during intensity-modulated radiotherapy for base of tongue cancer: Clinical implications for minimizing post-radiotherapy swallowing dysfunction.
Аннотация
BACKGROUND
The purpose of this study was to assess whether different tongue positions change the radiation doses to swallowing organs at risks: the pharyngeal constrictor, oral cavity, and larynx during intensity-modulated radiotherapy (IMRT) for base of tongue (BOT) cancer.
METHODS
IMRT plans with Tongue-out (IMRT-TO) and tongue-in position (IMRT-TI) was compared in 3 cases.
RESULTS
Distance from BOT to pharyngeal constrictor was increased to 1.8 ± 0.8 cm with IMRT-TO from 0.9 ± 0.6 cm with IMRT-TI (P < .01). Compared to IMRT-TI, IMRT-TO significantly decreased the radiation dose to the anterior oral cavity, oral tongue, superior pharyngeal constrictor, middle pharyngeal constrictor, and supraglottic larynx (all P ≤ .04). IMRT-TO also had a smaller volume irradiated than IMRT-TI to the anterior oral cavity and the oral tongue receiving ≥30 Gy (V30) and V35, and superior pharyngeal constrictor and middle pharyngeal constrictor for V55 and V65 (all P ≤ .04).
CONCLUSION
Dosimetric advantage with IMRT-TO over IMRT-TI may potentially reduce post-IMRT swallowing dysfunction in selected patients with BOT cancer.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.