Use and outcomes of cerebral embolic protection for transcatheter aortic valve replacement: A US nationwide study.

Khan Muhammad Zia, Zahid Salman, Khan Muhammad U, Kichloo Asim, Ullah Waqas, Sattar Yasar, Munir Muhammad Bilal, Singla Atul, Goldsweig Andrew M, Balla Sudarshan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Outcomes data on the use of cerebral embolic protection devices (CPDs) with transcatheter aortic valve replacement (TAVR) remain limited. Previous randomized trials were underpowered for primary outcomes of stroke prevention and mortality.

METHODS

The National Inpatient Sample and Nationwide Readmissions Database were queried from 2017 to 2018 to study utilization and inpatient mortality, neurological complications (ischemic stroke, hemorrhagic stroke, and transient ischemic attack), procedural complications, resource utilization, and 30-day readmissions with and without use of CPD. A 1:3 ratio propensity score matched model was created.

RESULTS

Among 108,315 weighted encounters, CPD was used in 4380 patients (4.0%). Adjusted mortality was lower in patients undergoing TAVR with CPD (1.3% vs. 0.5%, p < 0.01). Neurological complications (2.5% vs. 1.7%, p < 0.01), hemorrhagic stroke (0.2% vs. 0%, p < 0.01) and ischemic stroke (2.2% vs. 1.4%, p < 0.01) were also lower in TAVR with CPD. Multiple logistic regression showed CPD use was associated with lower adjusted mortality (odds ratio (OR], 0.34 [95% confidence interval [CI], 0.22-0.52), p < 0.01) and lower adjusted neurological complications (OR, 0.68 (95% CI, 0.54-0.85], p < 0.01). On adjusted analysis, 30-day all-cause readmissions (Hazard ratio, HR 0.839, [95% CI, 0.773-0.911], p < 0.01) and stroke (HR, 0.727 [95% CI, 0.554-0.955), p = 0.02) were less likely in TAVR with CPD.

CONCLUSION

We report real-world data on utilization and in-hospital outcomes of CPD use in TAVR. CPD use is associated with lower inpatient mortality, neurological, and clinical complications as compared to TAVR without CPD.

Для цитирования: Khan Muhammad Zia, Zahid Salman, Khan Muhammad U, Kichloo Asim, Ullah Waqas, Sattar Yasar, Munir Muhammad Bilal, Singla Atul, Goldsweig Andrew M, Balla Sudarshan. Use and outcomes of cerebral embolic protection for transcatheter aortic valve replacement: A US nationwide study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2021. DOI: 10.1002/ccd.29842.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.