Experience With the Pipeline Embolization Device for Posterior Circulations Aneurysms: A Multicenter Cohort Study.

Griessenauer Christoph J, Enriquez-Marulanda Alejandro, Taussky Philipp, Biswas Arundhati, Grandhi Ramesh, Xiang Sissi, Hong Tao, Rinaldo Lorenzo, Lanzino Giuseppe, Brinjikji Waleed, Burkhardt Jan-Karl, Kan Peter, Ghuman Mandeep, Yang Victor X D, Chen Karen, Aziz-Sultan Mohammad A, Ghorbani Mohammad, Schirmer Clemens M, Goren Oded, Dalal Shamsher S, Killer-Oberpfalzer Monika, Müller-Thies-Broussalis Erasmia, Koch Matthew J, Stapleton Christopher J, Patel Aman B, Foreman Paul M, Cress Marshall C, Hirschl Robert A, Krings Timo, Zhang Hongqi, Dmytriw Adam A

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The Pipeline Embolization Device (PED; Medtronic) has been used off-label for the treatment of challenging posterior circulation aneurysms. Data on this modality are primarily limited to small retrospective single-center series.

OBJECTIVE

To assess safety and efficacy of this treatment by establishing an international, multicenter collaboration.

METHODS

Consecutive posterior circulation aneurysms treated with the PED from 2012 to 2019 across 11 neurovascular centers were retrospectively reviewed. Baseline demographics, aneurysm and treatment characteristics, complications, occlusion status, and functional outcome were assessed.

RESULTS

There were 149 posterior circulation aneurysms treated with PED in 146 patients. A total of 24 (16.4%) patients presented with subarachnoid hemorrhage. Most aneurysms were dissecting/blister (36.2%) in morphology, followed by saccular (35.6%) and fusiform (28.2%). The most common locations were the vertebral (51.7%) and basilar arteries (22.8%). Complete or near-complete occlusion (>90%) was achieved in 90.9% of aneurysms at a median follow-up of 12 mo. Dissecting/blister aneurysms were most likely to occlude (P = .06). Symptomatic neurologic complications occurred in 9.4% of aneurysms, associated with larger size, ruptured presentation, presentations with brain stem compression, cranial nerve palsy, or stroke. Favorable functional outcome (modified Rankin Score 0-2) was achieved in 86.2% of patients. There were 6 fatalities of which 4 occurred in aneurysmal subarachnoid hemorrhage patients.

CONCLUSION

This multicenter study shows that PED for the treatment of posterior circulation is preferentially used for the treatment of fusiform and dissecting/blister aneurysm morphologies. Despite the challenges presented by these less-common morphologies, flow diversion may be performed with a neurologic complication rate of about 10% and favorable long-term aneurysm occlusion rates.

Для цитирования: Griessenauer Christoph J, Enriquez-Marulanda Alejandro, Taussky Philipp, Biswas Arundhati, Grandhi Ramesh, Xiang Sissi, Hong Tao, Rinaldo Lorenzo, Lanzino Giuseppe, Brinjikji Waleed, Burkhardt Jan-Karl, Kan Peter, Ghuman Mandeep, Yang Victor X D, Chen Karen, Aziz-Sultan Mohammad A, Ghorbani Mohammad, Schirmer Clemens M, Goren Oded, Dalal Shamsher S, Killer-Oberpfalzer Monika, Müller-Thies-Broussalis Erasmia, Koch Matthew J, Stapleton Christopher J, Patel Aman B, Foreman Paul M, Cress Marshall C, Hirschl Robert A, Krings Timo, Zhang Hongqi, Dmytriw Adam A. Experience With the Pipeline Embolization Device for Posterior Circulations Aneurysms: A Multicenter Cohort Study.. Neurosurgery. 2020. DOI: 10.1093/neuros/nyaa277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.