MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2020.05.094

Медицинская библиотека · International journal of cardiology · 2020

Safety of low intensity oral anticoagulant therapy in patients with bileaflet mechanical aortic valve prosthesis: A propensity weighted study.

Rubino Antonino S, Torella Michele, Della Ratta Ester E, Galbiati Denise, Della Corte Alessandro, Bancone Ciro, De Santo Luca S, De Feo Marisa

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Scarce data are available on the long-term outcomes of different regimens of oral anticoagulation in an all comer population of patients undergoing aortic valve replacement with a bileaflet mechanical heart valve.

METHODS

Outcomes of 88 patients discharged with a target INR of 2.0 (LOW-INR) were compared to 147 contemporary patients who have been recommended a target INR of 2.5 (CONV). Primary outcome was the composite of any thromboembolic or haemorrhagic events. Secondary outcomes were the individual components of the primary outcome, cardiovascular mortality and stroke. To reduce selection bias, a propensity weighted analysis was performed.

RESULTS

After inverse probability of treatment weighting, the primary endpoint occurred in 0.7% of patient in the LOW-INR group and in 7.0% in the CONV group (p = .0255). Linearized event rate were significantly lower in the LOW-INR group (primary endpoint: rate difference - 12.0 per 1000 patient/years, p = .0052; haemorrhage: -5.8 per 1000 patient/years, p = .0330; neurological events: -7.6 per 1000 patient/years, p = .0140). Conventional target INR was associated with an increased hazard of the composite endpoint (HR 11.193, 95% CI 1.424-88.003, p = .0217).

CONCLUSIONS

Lowering the intensity of oral anticoagulation resulted in a relevant clinical benefit of reduced rates of haemorrhagic and neurological adverse events in the mid-term follow-up. This report confirms the safety profile of the low INR regimen in an all comer population undergoing aortic valve replacement with an Abbott mechanical valve.

Для цитирования: Rubino Antonino S, Torella Michele, Della Ratta Ester E, Galbiati Denise, Della Corte Alessandro, Bancone Ciro, De Santo Luca S, De Feo Marisa. Safety of low intensity oral anticoagulant therapy in patients with bileaflet mechanical aortic valve prosthesis: A propensity weighted study.. International journal of cardiology. 2020. DOI: 10.1016/j.ijcard.2020.05.094.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.