MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajg.2014.04.006

Медицинская библиотека · Arab journal of gastroenterology : the official publication of the Pan-Arab Association of Gastroenterology · 2014

Haemoperitoneum post colonoscopy in a continuous ambulatory peritoneal dialysis patient.

Luni Faraz Khan, Bawany Muhammad Zohaib, Khan Abdur Rahman, Nawras Ali, Vetteth Sandeep

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We present the case of a patient on peritoneal dialysis (PD) who had an uneventful oesophagogastroduodenoscopy and colonoscopy. His peritoneal dialysis after colonoscopy had bright red peritoneal dialysate. The patient was completely asymptomatic and a CT scan was performed which did not reveal any retroperitoneal haematoma and showed no signs of perforation or splenic tear. His PD dialysate cleared up with time. We do not find any such case in the literature in which a patient has had haemoperitoneum after a colonoscopy without any obvious cause to account for it. Our patient was unique due to his CAPD in combination with his immunosuppression for his kidney transplant which may have predisposed him to the intraperitoneal bleed after colonoscopy or it may just have been a normal phenomenon after colonoscopy. More studies need to be done as the realisation of its pathology can prevent unnecessary testing and avoid patient and healthcare worker's anxiety.

Для цитирования: Luni Faraz Khan, Bawany Muhammad Zohaib, Khan Abdur Rahman, Nawras Ali, Vetteth Sandeep. Haemoperitoneum post colonoscopy in a continuous ambulatory peritoneal dialysis patient.. Arab journal of gastroenterology : the official publication of the Pan-Arab Association of Gastroenterology. 2014. DOI: 10.1016/j.ajg.2014.04.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.