Ophthalmic research · 2021

Ultrasound Cycloplasty in Chinese Glaucoma Patients: Results of a 6-Month Prospective Clinical Study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Luo Qin, Xue Wenwen, Wang Yulan, Chen Bin, Wang Shuangshuang, Dong Yiping, Ru Yan, Ge Ling

Аннотация

PURPOSE: The aim of this study was to evaluate the short-term efficacy and safety of ultrasound cycloplasty (UCP) procedure in Chinese glaucoma patients.

METHODS: As a single-center, prospective, noncomparative study, 23 eyes of 23 patients suffering from glaucoma with uncontrolled intraocular pressure (IOP) ≥21 mm Hg underwent a multidose UCP treatment with the activations of 6, 8, or10 sectors. Types of glaucoma include primary open-angle glaucoma (7/23), primary angle closure glaucoma (PACG) (9/23), and secondary glaucoma (SG) (7/23). A complete ophthalmic examination including intraocular pressure (IOP) measurements was performed before UCP procedure and at 1 day, 1 month, 3 months, and 6 months after the procedure. An IOP reduction of ≥20% and IOP >5 mm Hg without increasing hypotensive medication at the follow-up visit was defined as therapeutic success. The postoperative complications were also recorded and compared to baseline for safety evaluation.

RESULTS: The mean baseline IOP of 23 treated eyes was 37.2 ± 12.1 mm Hg. The IOP reduction after UCP procedure was 23, 49, 33, and 34% at 1 day, 1 month, 3 months, and 6 months, respectively. Thus, the corresponding overall therapeutic success rates reached 61% (14/23), 83% (19/23), 65% (15/23), and 61% (14/23), respectively. Baseline IOPs of 8- and 10-sector groups (37.0 ± 9.9 mm Hg and 50.1 ± 12.2 mm Hg) were significantly higher than that of 6 sector groups (30.1 ± 8.2 mm Hg). Therapeutic success rates of 6-, 8-, and 10-sector groups reached 44% (4/9), 56% (5/9), and 100% (5/5), respectively. There were the highest percentage of IOP reduction (50 and 41%) and therapeutic success rate (6/7; 86% and 7/9; 78%) in the SG group and PACG group, respectively. In addition, preoperative ocular pain symptoms of 4 patients were all disappeared within 1 week after UCP. No serious intraoperative or postoperative complications occurred.

CONCLUSION: UCP procedure is an effective and well-tolerated treatment to reduce IOP in Chinese glaucoma patients, which offered a novel alternative for glaucoma treatment.