Background

Middle ear (ME) pressure regulation has been suggested as a physiological mechanism that maintains pressure equilibrium between the ME and the ambient environment. This mechanism would be based on a complex sensorineural reflex loop composed of mechanoreceptors, an integrative center, and efferent neural pathways. Our aim was to demonstrate that hypoxic conditions, which would inhibit mechanoreceptors in general, similarly participate in the inhibition of the opening of the Eustachian tube (ET), and thus, to suggest that such receptors are involved in the overall regulation of ME pressure. Materials and

Methods

Among 14 healthy volunteers, tubomanometry was performed in normoxia followed by hypoxia, and 3 parameters were evaluated for each ear under each condition, allowing the evaluation of the reactivity of the system: ET opening latency index (R), the Index of Velum Contraction (IVC), and the latency of pressure instauration (C2-C1).

Results

Hypoxia induced a significant increase in the opening latency index of ET opening, without deleterious effects on the quality (IVC) and latency (C2-C1) of soft palate contraction.

Conclusions

Our study supports the theory of a sensorineural reflex loop and provides evidence for the existence of mechanoreceptors, whose function is modified by changes in oxygen partial pressure, able to collect information on pressure variations between the ME and the external environment.

Для цитирования: Alshukry Abdullah, Lagier Christine, Della Vedova Claire, Salburgo Florent, Lavieille Jean-Pierre, Montava Marion. The Effects of Hypoxia on Middle Ear Pressure Regulation.. High altitude medicine & biology. 2020. DOI: 10.1089/ham.2019.0043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.