MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jog.14544

Медицинская библиотека · The journal of obstetrics and gynaecology research · 2020

Palmer's test usefulness in the correct positioning of the Veress needle and the reduction of complications during laparoscopic access maneuvers.

Brenner-Anidjar Rony D, Rojo-Novo Sara, Frías-Sánchez Zoraida, Montaño-Serrano María, Pantoja-Rosso Francisco J, Terracina Dan, Pantoja-Garrido Manuel

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIM: Abdominal cavity access accounts for 50% of complications during laparoscopic surgery. Different safety maneuvers have been used to try to diminish these. Our study aims to establish the usefulness of Palmer's test in the correct positioning of the Veress needle and the reduction of complications during laparoscopic access maneuvers, when used in addition to the determination of intraabdominal pressure.

METHODS

Prospective observational analytic multi-centered cohort study with 370 patients undergoing gynecologic laparoscopy between July 2014 and November 2019, comparing the additional use of Palmer's test in 185 patients (Palmer-Test-Yes, PTY), with intraabdominal pressure determination alone in 185 patients (Palmer-Test-No, PTN).

RESULTS

Intergroup homogeneity was described for the basic characteristics of both population samples, except for mean age and percentage of previous laparotomy. A total of 19 complications were recorded, 10 in PTY and 9 in PTN, with no significant differences (P = 0.814). No differences were found in the analysis of these complications, except for the rate of conversion to laparotomy, which occurred four times in the PTY group and none in PTN (P = 0.044). Furthermore, no differences were found once fixed for the history of previous laparotomy (P = 514.), nor for the percentage of successful access after the first attempt between both groups (P = 0.753).

CONCLUSION

Palmer's test, when used in addition to intraabdominal pressure determination, has not shown to be effective in preventing failed access to abdominal cavity or reducing complications associated with access maneuvers with the Veress needle. Hence, its systematic use is not justified, since it could generate a sense of false security.

Для цитирования: Brenner-Anidjar Rony D, Rojo-Novo Sara, Frías-Sánchez Zoraida, Montaño-Serrano María, Pantoja-Rosso Francisco J, Terracina Dan, Pantoja-Garrido Manuel. Palmer's test usefulness in the correct positioning of the Veress needle and the reduction of complications during laparoscopic access maneuvers.. The journal of obstetrics and gynaecology research. 2020. DOI: 10.1111/jog.14544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.