MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jogoh.2020.101823

Медицинская библиотека · Journal of gynecology obstetrics and human reproduction · 2020

Outpatient versus inpatient balloon catheter insertion for labor induction: A systematic review and meta-analysis of randomized controlled trials.

Abdelhakim Ahmed Mohamed, Shareef Mohammad Abrar, AlAmodi Abdulhadi A, Aboshama Rehab Abdelhamid, Fathi Mohamed, Abbas Ahmed M

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare between outpatient and inpatient balloon catheter insertion for labor induction.

METHODS

We searched in four different databases for the available trials during May 2020. We included randomized controlled trials (RCTs) that compared outpatient to inpatient balloon catheter for induction of labor. We extracted the available data from the included studies and pooled them in meta-analysis using RevMan software. The dichotomous data were pooled as risk ratio (RR) and the continuous data were pooled as mean difference (MD) with the corresponding 95% confidence intervals (CI).Our primary outcome was the rate of cesarean delivery. Our secondary outcomes were the length of hospital stay, Bishop score, and different adverse events including postpartum hemorrhage, Apgar score less than 7 at 5 minutes, and chorioamnionitis.

RESULTS

Eight RCTs with a total number of 740patients were included. The cesarean delivery rate was significantly reduced among outpatient balloon catheter compared to inpatient balloon catheter (RR = 0.63, 95% CI [0.46, 0.86], p = 0.004). Outpatient balloon catheter was associated with shorter hospital stay duration in comparison with inpatient group (MD= -0.38, 95% CI [-0.61, -0.14], p = 0.002). Outpatient group was linked to a more favorable increase in Bishop score (MD = 0.88, 95% CI [0.78, 0.98], p>0.001). There were no significant differences between both groups regarding different adverse events.

CONCLUSION

Outpatient balloon catheter priming is safe and effective in reducing cesarean delivery rates and shortening the length of hospital stay with a better Bishop score.

Для цитирования: Abdelhakim Ahmed Mohamed, Shareef Mohammad Abrar, AlAmodi Abdulhadi A, Aboshama Rehab Abdelhamid, Fathi Mohamed, Abbas Ahmed M. Outpatient versus inpatient balloon catheter insertion for labor induction: A systematic review and meta-analysis of randomized controlled trials.. Journal of gynecology obstetrics and human reproduction. 2020. DOI: 10.1016/j.jogoh.2020.101823.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.