Parametric Cardiac Imaging with 18F-Flutemetamol PET to Evaluate the Impact of Tafamidis in Patients with Transthyretin Cardiac Amyloidosis.

Liu Qiong, Shi Tiantian, Gravel Paul, Sharma Aakanksha, De Freitas Cinthia, Fazzone-Chettiar Ramesh, Van Laere Koen, Baldick Andrea, Kattan Cesia Gallegos, Guo Xueqi, Guo Liang, Xie Huidong, Chen Xiongchao, Zhou Bo, Liu Yi-Hwa, Carson Richard E, Liu Chi, Miller Edward

СтатьяПеревод пока не подготовлен

Аннотация

In transthyretin cardiac amyloidosis (ATTR-CA), static 18F-flutemetamol PET-derived SUVs do not adequately capture intricate tracer kinetics, limiting the accurate quantification of amyloid burden. We developed dynamic parametric PET imaging methods to improve the quantification of myocardial amyloid burden in ATTR-CA.

Methods

Twelve treatment-naïve ATTR-CA patients underwent 60-min dynamic cardiac 18F-flutemetamol PET/CT at baseline and after 6 mo of treatment with tafamidis. Image-derived input functions were corrected for blood-to-plasma ratios and metabolites. Myocardium blood volume fraction was estimated using a 1-tissue compartment model (0-10 min), and volume-of-distribution (V T) images were generated using the multilinear analysis 1 method (2-20 min). V T was correlated with echocardiography, 82Rb myocardial blood flow, and biomarkers.

Results

The mean myocardial blood volume fraction was 22% ± 6%. A 2-tissue reversible model with metabolite- and plasma-corrected input functions provided optimal kinetic fits. Multilinear analysis 1 using 2- to 20-min PET data produced V T images with the lowest variance. V T decreased significantly after 6 mo of treatment with tafamidis (from 2.11 ± 0.33 to 1.96 ± 0.20, P = 0.046).

Conclusion

Dynamic 18F-flutemetamol PET enabled robust quantification of myocardial amyloid burden using metabolite-corrected 2-compartment modeling. V T imaging demonstrated sensitivity to treatment-related changes in ATTR-CA.

Для цитирования: Liu Qiong, Shi Tiantian, Gravel Paul, Sharma Aakanksha, De Freitas Cinthia, Fazzone-Chettiar Ramesh, Van Laere Koen, Baldick Andrea, Kattan Cesia Gallegos, Guo Xueqi, Guo Liang, Xie Huidong, Chen Xiongchao, Zhou Bo, Liu Yi-Hwa, Carson Richard E, Liu Chi, Miller Edward. Parametric Cardiac Imaging with 18F-Flutemetamol PET to Evaluate the Impact of Tafamidis in Patients with Transthyretin Cardiac Amyloidosis.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2026. DOI: 10.2967/jnumed.125.270003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.