MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ija.ija_104_18

Медицинская библиотека · Indian journal of anaesthesia · 2018

Perioperative monitoring of intracranial pressure using optic nerve sheath diameter in paediatric liver transplantation.

Pal Atish, Dhar Purnima, Goyal Neerav

СтатьяПеревод пока не подготовлен

Аннотация

An elevation of intracranial pressure (ICP) secondary to cerebral oedema is a major contributor to morbidity and mortality in acute liver failure (ALF). We present a case of ICP monitoring with ocular ultrasonography in a 2-year-old child with ALF for liver transplantation. Since invasive ICP monitoring was risky considering the level of coagulopathy, optic nerve sheath diameter (ONSD) monitoring was done by ultrasound. A value of 4.5 mm was chosen as the cut-off for an ICP >20 mmHg in this child and was checked at regular intervals during the surgery. Ultrasonographic ONSD assessment can be a useful modality in liver transplant recipients, with severe coagulopathy and high ICP. In our specific patient scenario, ocular ultrasound proved to be a valuable safe and noninvasive monitoring tool in this paediatric patient.

Для цитирования: Pal Atish, Dhar Purnima, Goyal Neerav. Perioperative monitoring of intracranial pressure using optic nerve sheath diameter in paediatric liver transplantation.. Indian journal of anaesthesia. 2018. DOI: 10.4103/ija.ija_104_18.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.