Eye & contact lens · 2018
Multicenter Testing of a Risk Assessment Survey for Soft Contact Lens Wearers With Adverse Events: A Contact Lens Assessment in Youth Study.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sorbara Luigina, Zimmerman Aaron B, Mitchell G Lynn, Richdale Kathryn, Lam Dawn Y, Kinoshita Beth T, Chalmers Robin L, Wagner Heidi
Аннотация
PURPOSE: To test the ability of responses to the Contact Lens Assessment in Youth (CLAY) Contact Lens Risk Survey (CLRS) to differentiate behaviors among participants with serious and significant (S&S) contact lens-related corneal inflammatory events, those with other events (non-S&S), and healthy controls matched for age, gender, and soft contact lens (SCL) wear frequency.
METHODS: The CLRS was self-administered electronically to SCL wearers presenting for acute clinical care at 11 clinical sites. Each participant completed the CLRS before their examination. The clinician, masked to CLRS responses, submitted a diagnosis for each participant that was used to classify the event as S&S or non-S&S. Multivariate logistic regression analyses were used to compare responses.
RESULTS: Comparison of responses from 96 participants with S&S, 68 with non-S&S, and 207 controls showed that patients with S&S were more likely (always or fairly often) to report overnight wear versus patients with non-S&S (adjusted odds ratio [aOR], 5.2; 95% confidence interval [CI], 1.4-18.7) and versus controls (aOR, 5.8; CI, 2.2-15.2). Patients with S&S were more likely to purchase SCLs on the internet versus non-S&S (aOR, 4.9; CI, 1.6-15.1) and versus controls (aOR, 2.8; CI, 1.4-5.9). The use of two-week replacement lenses compared with daily disposables was significantly higher among patients with S&S than those with non-S&S (aOR, 4.3; CI, 1.5-12.0). Patients with S&S were less likely to regularly discard leftover solution compared with controls (aOR, 2.5; CI, 1.1-5.6).
CONCLUSIONS: The CLRS is a clinical survey tool that can be used to identify risky behaviors and exposures directly associated with an increased risk of S&S events.
METHODS: The CLRS was self-administered electronically to SCL wearers presenting for acute clinical care at 11 clinical sites. Each participant completed the CLRS before their examination. The clinician, masked to CLRS responses, submitted a diagnosis for each participant that was used to classify the event as S&S or non-S&S. Multivariate logistic regression analyses were used to compare responses.
RESULTS: Comparison of responses from 96 participants with S&S, 68 with non-S&S, and 207 controls showed that patients with S&S were more likely (always or fairly often) to report overnight wear versus patients with non-S&S (adjusted odds ratio [aOR], 5.2; 95% confidence interval [CI], 1.4-18.7) and versus controls (aOR, 5.8; CI, 2.2-15.2). Patients with S&S were more likely to purchase SCLs on the internet versus non-S&S (aOR, 4.9; CI, 1.6-15.1) and versus controls (aOR, 2.8; CI, 1.4-5.9). The use of two-week replacement lenses compared with daily disposables was significantly higher among patients with S&S than those with non-S&S (aOR, 4.3; CI, 1.5-12.0). Patients with S&S were less likely to regularly discard leftover solution compared with controls (aOR, 2.5; CI, 1.1-5.6).
CONCLUSIONS: The CLRS is a clinical survey tool that can be used to identify risky behaviors and exposures directly associated with an increased risk of S&S events.