Phase-Inversion In Situ Implants for Dental Drug Delivery: A QbD-Guided In Vitro Technological Evaluation.

Bakhrushina Elena O, Sakharova Polina S, Kotilevskaya Mariya V, Mikhel Iosif B, Brkich Galina E, Pyatigorskaya Natalya V, Brago Anzhela S, Evzikov Grigory Yu, Vasiliev Yuriy L

СтатьяПеревод пока не подготовлен

Аннотация

Phase-inversion in situ implants (PIISIs) represent a versatile polymer platform in which the rational choice of matrix former and solvent system directly governs the macroscopic properties of the resulting depot. This study applied a Quality by Design (QbD) approach to rationalize a bleached shellac-based PIISI, with particular focus on the physicochemical interactions between the polymer and the injection vehicle. Bleached shellac-a natural, low-cost, biodegradable oligomeric resin bearing -COOH, -OH, and ester functional groups-was selected as the matrix former and screened in seven neat solvents and five 1:1 binary combinations at 25% (m/m). Twelve formulations were evaluated against a predefined set of critical quality attributes, including injectability, phase-inversion kinetics, solvent diffusion volume, and implant structure (n = 5 per formulation; mean ± standard deviation (SD); one-way analysis of variance (ANOVA) with Tukey's post hoc test, p < 0.05). Three lead solvent systems-propylene glycol/N-methylpyrrolidone (PG+NMP), PG/dimethyl sulfoxide (PG+DMSO), and DMSO/benzyl alcohol (DMSO+BA)-were identified as those providing an optimal balance between hydrogen-bond donor/acceptor solvation and controlled solvent extraction. In the second stage, shellac concentration (20-35%) was optimized, with 30% shellac in PG+NMP yielding the fastest phase inversion (~50 s), a structurally uniform matrix, and the lowest swelling (22%). A working mechanistic framework consistent with all observed critical quality attribute (CQA) trends in which solvent hydrogen-bond donor/acceptor balance and water miscibility govern implant architecture is proposed, and it is intended as a hypothesis-generating basis for the rational design of PIISI formulations; direct validation by spectroscopic, thermal-analytical, and biological methods is identified as the next step. The developed formulations are presented as a preliminary physicochemical platform; biological validation (in vitro cytocompatibility and inflammatory response assessment) is required before the system can be considered a validated formulation for dental drug delivery.

Для цитирования: Bakhrushina Elena O, Sakharova Polina S, Kotilevskaya Mariya V, Mikhel Iosif B, Brkich Galina E, Pyatigorskaya Natalya V, Brago Anzhela S, Evzikov Grigory Yu, Vasiliev Yuriy L. Phase-Inversion In Situ Implants for Dental Drug Delivery: A QbD-Guided In Vitro Technological Evaluation.. Polymers. 2026. DOI: 10.3390/polym18121420.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.