MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/all.16339

Медицинская библиотека · Allergy · 2024

Improved quality control of allergen products: Assessing the molecular allergen composition by mass spectrometry.

Augustin Steffen, Eichhorn Thomas, Wald Martin, Fischer Frank, Jutel Marek, Pfaar Oliver, Willers Christoph

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Natural allergen sources contain a variety of allergens, against which allergic subjects have developed individual sensitization profiles. Ideal allergen products for skin prick testing (SPT) and allergen immunotherapy (AIT) should contain the complete set of allergens of the respective allergen sources to cover all sensitization profiles. However, commercially available allergen products were shown to vary regarding their allergen composition.

METHODS

The qualitative allergen composition of different SPT and AIT products produced from pollen of grasses, birch, mugwort and from house dust mites was assessed by a consistent high-resolution liquid chromatography-coupled tandem mass spectrometry method (LC-MS/MS).

RESULTS

All major, mid-tier and most minor allergens were detected in each of the investigated three batches of SPT and AIT products, demonstrating the completeness of the allergen composition and a high degree of batch-to-batch consistency.

CONCLUSION

This is the first study using a single consistent high-resolution LC-MS/MS method to provide solid data on the qualitative allergen composition of SPT and AIT products manufactured from various common allergen sources. The applied method showed high reliability in qualitative batch-to-batch consistency testing and can be performed fast and with high throughput. High-resolution LC-MS/MS is applicable for process development and quality control to ensure market availability of allergen products corresponding to the composition of the respective natural allergen sources.

Для цитирования: Augustin Steffen, Eichhorn Thomas, Wald Martin, Fischer Frank, Jutel Marek, Pfaar Oliver, Willers Christoph. Improved quality control of allergen products: Assessing the molecular allergen composition by mass spectrometry.. Allergy. 2024. DOI: 10.1111/all.16339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.