Surgery today · 2025
Use of a reinforced triple-row stapler with a powered stapling system reduces the occurrence of postoperative pancreatic fistula after distal pancreatectomy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kobayashi Shinjiro, Ida Keisuke, Umezawa Saori, Nakahara Kazunari, Tateishi Keisuke, Norose Tomoko, Ohike Nobuyuki, Morimoto Tsuyoshi, Mikami Shinya, Otsubo Takehito
Аннотация
PURPOSE: Stapled closure is the standard technique for pancreatic resection via distal pancreatectomy (DP). The Signia™ Stapling System allows for adaptive stapling based on real-time tissue resistance. This study aims to investigate whether DP using the Signia™ system could reduce the incidence of clinically relevant post-operative pancreatic fistula (CR-POPF).
METHODS: We retrospectively analyzed 53 patients who underwent DP between 2020 and 2025. 26 patients underwent DP using the Signia™ Stapling System (powered stapler group), and 27 patients using a manual stapler (manual stapler group). The primary outcome was the CR-POPF rate.
RESULTS: In the powered stapler group, 38.5% of patients developed biochemical leakage, but no cases of CR-POPF were observed. In contrast, the manual stapler group had a CR-POPF rate of 18.5% (p = 0.021). A receiver operating characteristic curve was generated to determine the pancreatic thickness threshold predictive of CR-POPF. The calculated cut-off value was 16 mm. In the powered group, there were no cases of CR-POPF even if the pancreatic thickness at the resection line was ≥ 16 mm.
CONCLUSIONS: The use of a powered stapler may therefore help reduce the risk of POPF associated with variability in the thickness and hardness of the pancreas during DP.
METHODS: We retrospectively analyzed 53 patients who underwent DP between 2020 and 2025. 26 patients underwent DP using the Signia™ Stapling System (powered stapler group), and 27 patients using a manual stapler (manual stapler group). The primary outcome was the CR-POPF rate.
RESULTS: In the powered stapler group, 38.5% of patients developed biochemical leakage, but no cases of CR-POPF were observed. In contrast, the manual stapler group had a CR-POPF rate of 18.5% (p = 0.021). A receiver operating characteristic curve was generated to determine the pancreatic thickness threshold predictive of CR-POPF. The calculated cut-off value was 16 mm. In the powered group, there were no cases of CR-POPF even if the pancreatic thickness at the resection line was ≥ 16 mm.
CONCLUSIONS: The use of a powered stapler may therefore help reduce the risk of POPF associated with variability in the thickness and hardness of the pancreas during DP.