Biosensors & bioelectronics · 2026
Low-potential ciprofloxacin detection in wound exudate via docking-guided molecular imprinting and redox-active reporter transduction.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lu Dingxi, Wang Bingxuan, Fu Jie, Lin Lizhi, Gegeen Uul, Pan Wen, Mu Fanyu, Ding Yihong, Deng Shouzhe, Wang Jiawang, Li Shuang
Аннотация
Accurate quantification of ciprofloxacin (CIP) in wound exudate is important for assessing local antibiotic exposure and supporting rational wound infection management. However, direct electrooxidation of CIP requires a high working potential and is susceptible to interference from endogenous electroactive species in complex wound matrices. Here, we developed a redox-active reporter-mediated molecularly imprinted electrochemical sensor (RAR-MIECS) for low-potential CIP quantification across non-infected and infected wound microenvironments. Moldina-assisted multiple-ligand docking guided the construction of a dual-monomer imprinted interface composed of 3-aminophenylboronic acid and pyrrole for selective CIP recognition. Stepwise electrodeposition of RAR films converted CIP rebinding-induced interfacial blocking into a signal-off response near 0 V. Compared with direct CIP electrooxidation, RAR-mediated transduction shifted the operating potential window by approximately 0.7 V toward negative potentials and increased the current difference by approximately 10-fold. Because distinct differential pulse voltammetric responses were observed in simulated non-infected and infected wound fluids, microenvironment-matched calibration relationships were established at pH 6.5 and 7.4. The RAR-MIECS showed linear responses over 0.001-100 μM in both media, with detection limits of 0.142 and 0.126 nM, respectively, together with good selectivity, interference resistance, reproducibility, and stability. Spike-recovery analysis in murine wound exudate samples yielded recoveries of 98.0%-106.0% for 5-20 μM CIP, with relative standard deviations below 7%. This microenvironment-matched platform provides a low-interference strategy for reliable CIP quantification in complex wound-exudate matrices and offers an analytical basis for future concentration-guided anti-infective wound management.