DOI 10.1097/ico.0000000000001999
Five-Year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty.
Аннотация
PURPOSE: To report 5-year outcomes of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) with a central graft thickness intended to be <100 μm.
METHODS
This retrospective, consecutive, interventional case series included 354 eyes with endothelial decompensation due to various causes (Fuchs endothelial dystrophy, pseudophakic or aphakic bullous keratopathy, failed previous graft, herpetic endothelitis, or buphthalmos). Donor tissue was prepared using the microkeratome-assisted double-pass technique aiming at a graft thickness <100 μm. The Descemet membrane was stripped under air. The graft was delivered into the anterior chamber using the pull-through technique through a 3.2-mm clear corneal incision using a modified Busin glide. The best spectacle-corrected visual acuity (BSCVA), endothelial cell loss, graft survival rates, and immunologic rejection rates were evaluated.
RESULTS
Follow-up data at 1, 2, 3, and 5 years after UT-DSAEK were collected from 214, 172, 147, and 105 eyes, respectively. After excluding eyes with comorbidities, BSCVA better than or equal to 20/20 was recorded in 36.3%, 37.4%, 46.4%, and 53.4% of eyes, respectively, whereas BSCVA better than or equal to 20/40 was documented in 95.5%, 95.3%, 96.0%, and 96.6% of eyes, respectively. The mean endothelial cell loss was 35.4%, 42.3%, 43.3%, and 52.3%; Kaplan-Meier graft survival probability was 99.1%, 96.2%, 94.2%, and 94.2%, and Kaplan-Meier cumulative probability of a rejection episode was 3.4%, 4.3%, 5%, and 6.9% at 1, 2, 3, and 5 years, respectively.
CONCLUSIONS
UT-DSAEK grafts allow excellent 5-year outcomes, including BSCVA, endothelial cell density, and survival rates comparable with those recorded post-Descemet membrane endothelial keratoplasty, but with a higher immunologic rejection rate.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.