MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.icl.0000242166.09513.aa

Медицинская библиотека · Eye & contact lens · 2007

The impact of silicone hydrogel materials on overnight corneal swelling.

Steffen Robert B, Schnider Cristina M

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To identify the corneal swelling response associated with silicone hydrogel contact lens wear.

METHODS

Twenty-five subjects were recruited to participate in this single-center, controlled, single-masked, clinical trial. The corneal swelling response was evaluated by central corneal pachymetry after overnight wear of balafilcon A, etafilcon A, lotrafilcon A, senofilcon A, and no lens wear. More specifically, after 8 hours of closed-eye wear of each material, corneal thickness was measured immediately on eye opening, in addition to the first 4 hours of open-eye wear. Paired t tests were used to compare the swelling response from each condition to that associated with senofilcon A, and given the numerous statistical comparisons, a P value of <or=0.01 was considered significant.

RESULTS

At eye opening, there was no difference in the swelling response when comparing balafilcon A (1.35%), lotrafilcon A (1.22%), or no lens wear (0.77%) to senofilcon A (1.40%), although the swelling response associated with etafilcon A was significantly greater (P<0.001) than that associated with senofilcon A. There were no differences between balafilcon A, lotrafilcon A, and no lens wear compared to senofilcon A during the open-eye deswelling period. However, 1 hour after eye opening, corneal swelling remained significantly greater with etafilcon A than with senofilcon A (1.76% vs. -0.51%, respectively, P=0.01), although no other time-specific comparisons differed.

CONCLUSIONS

Silicone hydrogel lenses, with high oxygen transmissibilities, are associated with very little corneal swelling after overnight wear of the lenses.

Для цитирования: Steffen Robert B, Schnider Cristina M. The impact of silicone hydrogel materials on overnight corneal swelling.. Eye & contact lens. 2007. DOI: 10.1097/01.icl.0000242166.09513.aa.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.