Sidora Gurnish, Haley Anna L, Cancelliere Nicole M, Pereira Vitor M, Steinman David A

Аннотация

BACKGROUND: Venous sinus stenosis can be associated with cerebrovascular disorders. Understanding the role of blood flow disturbances in these disorders is often hampered by the lack of patient-specific flow rates. Our goal was to demonstrate the impact of this by predicting individual flow rates retrospectively from routine manometry and angiography.

METHODS: Ten cases, spanning a range of stenosis severities and pressure gradients, were selected from a cohort of patients who had undergone venous stenting for pulsatile tinnitus. Lumen geometries were digitally segmented from CT venograms. A simplified Bernoulli formula was derived to estimate individual cycle-average flow rates from clinical pressure gradients and minimum lumen cross-section areas. High-fidelity pulsatile computational fluid dynamics (CFD) simulations were performed to compare predictions of flow disturbances using generic versus individual flow rates, and to validate the Bernoulli formula.

RESULTS: Individual flow rates derived from the Bernoulli formula deviated by up to 47% from the assumed generic flow rate, resulting in substantial differences in CFD predictions of post-stenotic flow instabilities. Pressure gradients estimated by the simplified Bernoulli formula were, however, highly predictive of pressure gradients from the full CFD simulations (R2=0.95; slope=0.98, 95% CI 0.88 to 1.09).

CONCLUSIONS: A simple Bernoulli formula can predict CFD-estimated trans-stenotic pressure gradients in realistic venous geometries. As demonstrated here, this may be used to recover individual flow rates from routine-but-invasive clinical measurements; however, it also suggests a simpler path towards non-invasive estimation of trans-stenotic pressure gradients that may avoid some of the challenges associated with 4D flow MRI approaches.