DOI 10.1016/j.diii.2024.05.005

Медицинская библиотека · Diagnostic and interventional imaging · 2024

Temporal bone remodeling is an indicator of transverse sinus stenosis on computed tomography.

Guédon Alexis, Arpaia Francesco, Thépenier Cédric, Eliezer Michael, Villas Boas Alves Saulo, Saint-Maurice Jean-Pierre, Houdart Emmanuel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to identify potential association between transverse sinus stenosis (TSS) and temporal bone thinning downstream of TSS on computed tomography (CT).

MATERIALS AND

METHODS

Clinical and radiological data of patients with venous pulsatile tinnitus due to TSS (TSS group) and treated with stenting from 2019 to 2022 were retrospectively collected. An age-matched control group of patients with venous or neutral pulsatile tinnitus (control group) was built. CT measurements of temporal bone thickness were performed at the level of transverse-sigmoid sinus junction (E1) and the occipitomastoid suture (E2). E1; E2 and E1/E2 ratios obtained in TSS and control groups were compared.

RESULTS

A total of 122 patients with venous pulsatile tinnitus were included. There were 56 patients with TSS (TSS group; 56 women; mean age, 35.5 ± 11.3 [standard deviation] years) and 66 patients without TSS (control group; 54 women; mean age, 37.7 ± 10.5 [standard deviation] years). E1 measurements and E1/E2 ratios on the symptomatic and dominant sides were significantly lower in the TSS group by comparison with the contralateral side of the same group (P < 0.05) and the ipsilateral side of the control group (P < 0.05). There were no differences in median E2 values between the TSS group (6.8 mm; range: 3.5-10.8 mm) and the control group (7.1 mm; range: 2.9-11.2 mm) (P = 0.098). E1 = 0 mm was found only in the TSS group. At receiver operating characteristic (ROC) analysis, an E1/E2 ratio threshold of 0.562 maximized the ability to predict presence of TSS. An E1/E2 ratio < 0.562 was predictive of symptomatic TSS with an accuracy of 74% (95% confidence interval: 65-82%). The AUC for the diagnosis of TSS was 0.807 (95% CI: 0.729-0.885).

CONCLUSION

Temporal bone thickness is significantly reduced downstream of the stenosis on the pulsatile tinnitus side and may be a good indicator of symptomatic TSS.

Для цитирования: Guédon Alexis, Arpaia Francesco, Thépenier Cédric, Eliezer Michael, Villas Boas Alves Saulo, Saint-Maurice Jean-Pierre, Houdart Emmanuel. Temporal bone remodeling is an indicator of transverse sinus stenosis on computed tomography.. Diagnostic and interventional imaging. 2024. DOI: 10.1016/j.diii.2024.05.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.