OBJECTIVE

This study aims to control all hearing thresholds, including extended high frequencies (EHFs), presents stimuli of varying difficulty levels, and measures electroencephalography (EEG) and pupillometry responses to determine whether listening difficulty in tinnitus patients is effort or fatigue-related.

METHODS

Twenty-one chronic tinnitus patients and 26 matched healthy controls having normal pure-tone averages with symmetrical hearing thresholds were included. Subjects were evaluated with 0.125-20 kHz pure-tone audiometry, Montreal Cognitive Assessment Test (MoCA), Tinnitus Handicap Inventory (THI), EEG, and pupillometry.

RESULTS

Pupil dilatation and EEG alpha power during the "encoding" phase of the presented sentence in tinnitus patients were less in all listening conditions (p < .05). Also, there was no statistically significant relationship between EEG and pupillometry components for all listening conditions and THI or MoCA (p > .05).

CONCLUSION

EEG and pupillometry results under various listening conditions indicate potential listening effort in tinnitus patients even if all frequencies, including EHFs, are controlled. Also, we suggest that pupillometry should be interpreted with caution in autonomic nervous system-related conditions such as tinnitus.

Для цитирования: Sendesen Eser, Turkyilmaz Didem. Investigation of the behavior of tinnitus patients under varying listening conditions with simultaneous electroencephalography and pupillometry.. Brain and behavior. 2024. DOI: 10.1002/brb3.3571.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.