MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000000146

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2014

Noninvasive assessment of retinal vascular oxygen content among normal and diabetic human subjects: a study using hyperspectral computed tomographic imaging spectroscopy.

Kashani Amir H, Lopez Jaime Gilberto R, Saati Saloomeh, Martin Gabriel, Varma Rohit, Humayun Mark S

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This pilot study was aimed to demonstrate the clinical feasibility of using hyperspectral computed tomographic spectroscopy to measure blood oxygen content in human retinal vessels.

METHODS

All procedures were performed under a University of Southern California Institutional Review Board-approved protocol and after obtaining informed consent. Fifty-seven subjects with and without diabetic retinopathy were dilated for standard fundus photography. Fundus photographs and retinal vascular oxygen measurements (oximetry) were made using a custom-made hyperspectral computed tomographic imaging spectrometer coupled to a standard fundus camera. Oximetry measurements were made along arteries (Aox) and veins (Vox) within vessel segments that were 1 to 2 disk diameters from the optic disk.

RESULTS

For all control subjects (n = 45), mean Aox and Vox were 93 ± 7% and 65 ± 5% (P = 0.001), respectively. For all diabetic subjects (n = 12), mean Aox and Vox were 90 ± 7% and 68 ± 5% (P = 0.001), respectively. In subjects with proliferative diabetic retinopathy, Aox was significantly lower, and Vox was significantly higher than other groups (85 ± 4% and 71 ± 4%, respectively; P = 0.04, analysis of variance). There was a highly significant difference in the arteriovenous difference between subjects with proliferative diabetic retinopathy and those in the control group (14 vs. 26%, P = 0.003).

CONCLUSION

Hyperspectral computed tomographic spectroscopy is a clinically feasible method for measurement and analysis of vascular oxygen content in retinal health and disease. This study uses the techniques relevant to oximetry; however, the breadth of spectral data available through this method may be applicable to study other anatomical and functional features of the retina in health and disease.

Для цитирования: Kashani Amir H, Lopez Jaime Gilberto R, Saati Saloomeh, Martin Gabriel, Varma Rohit, Humayun Mark S. Noninvasive assessment of retinal vascular oxygen content among normal and diabetic human subjects: a study using hyperspectral computed tomographic imaging spectroscopy.. Retina (Philadelphia, Pa.). 2014. DOI: 10.1097/iae.0000000000000146.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.