MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.13802

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2024

Clinical utility of maternal TORCH screening in fetal growth restriction: A retrospective two-centre study.

Wade Christine A, Atkinson Naomi, Holmes Natasha E, Hui Lisa

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to evaluate the indications for maternal TORCH (Toxoplasma gondii, rubella, cytomegalovirus (CMV), and herpes simplex virus (HSV)) serology, with a focus on the yield in isolated fetal growth restriction (FGR).

MATERIALS AND

METHODS

A retrospective review of antenatal TORCH testing between January 2014 and December 2018 was carried out at two hospitals in Melbourne, Australia. TORCH testing ordered for pregnancy losses and stillbirth was excluded.

RESULTS

Medical records of 718 pregnancies were reviewed, representing 760 fetuses. Isolated FGR was the indication for TORCH screening in 71.2% of pregnancies. Screens ordered for isolated FGR were positive in 7.4% (95% CI 5.5-10.0%). There were 49 positive maternal immunoglobulin M (CMV = 34, Toxoplasma = 15). Two acute maternal infections during pregnancy were diagnosed (CMV = 1, Toxoplasma = 1), with both screens ordered to assess symptomatic maternal illness. There was one neonatal CMV infection, born to a woman with symptomatic primary CMV. No maternal or neonatal rubella or HSV infections were identified. We found a diagnostic yield of TORCH screening for isolated FGR of 0.0% (95% CI 0.00-0.8%). An estimated AUD$64 269.75 was expended on maternal TORCH screens in this study.

CONCLUSION

Maternal TORCH testing for isolated FGR is of no diagnostic yield and should be abandoned.

Для цитирования: Wade Christine A, Atkinson Naomi, Holmes Natasha E, Hui Lisa. Clinical utility of maternal TORCH screening in fetal growth restriction: A retrospective two-centre study.. The Australian & New Zealand journal of obstetrics & gynaecology. 2024. DOI: 10.1111/ajo.13802.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.