MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000002338

Медицинская библиотека · Cornea · 2020

The Influence of Speed During Stripping in Descemet Membrane Endothelial Keratoplasty Tissue Preparation.

Borroni Davide, Gadhvi Kunal, Wojcik Gabriela, Pennisi Flavia, Vallabh Neeru A, Galeone Alessandra, Ruzza Alessandro, Arbabi Esmaeil, Menassa Nardine, Kaye Stephen, Ponzin Diego, Ferrari Stefano, Romano Vito

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate whether the speed of stripping a Descemet membrane endothelial keratoplasty graft influences the graft scroll width.

METHODS

Human corneas suitable for research were selected for the study. Pairs of corneas were randomly divided into 2 groups: 1 cornea was stripped with a slow speed (group 1) and the contralateral with a fast speed (group 2). Slow speed was defined as the total time greater than 150 seconds or speed <0.057 mm/s. Fast peeling was defined as less than 75 seconds or speed >0.11 mm/s. The grafts acquired were evaluated by microscopy for the graft scroll width and endothelial cell density change pre- and post-preparation.

RESULTS

Twenty corneas of 10 donors were included in the analysis. The mean donor age was 68.6 ± 7.58 years. The mean total time of the tissue preparation in group 1 was 282.7 ± 28 seconds and in group 2 was 126 ± 50 seconds (P-value = 0.00000047). The mean speed of stripping in group 1 was 0.045 ± 0.006 mm/s and in group 2 was 0.266 ± 0.093 mm/s (P-value = 0.000027). The graft width in group 1 was 6.4 ± 0.92 mm and in group 2 was 2.87 ± 0.32 mm (P-value = 0.00000014). The mean endothelial cell loss in group 1 was 389 ± 149 cells/mm and in group 2 was 186 ± 63.44 cells/mm (P-value = 0.00134).

CONCLUSION

We found a correlation between the speed of stripping, scroll width, and endothelial cell loss. Slow-peeled Descemet membrane endothelial keratoplasty grafts result in a wider scroll width but were associated with a greater reduction in endothelial cell density.

Для цитирования: Borroni Davide, Gadhvi Kunal, Wojcik Gabriela, Pennisi Flavia, Vallabh Neeru A, Galeone Alessandra, Ruzza Alessandro, Arbabi Esmaeil, Menassa Nardine, Kaye Stephen, Ponzin Diego, Ferrari Stefano, Romano Vito. The Influence of Speed During Stripping in Descemet Membrane Endothelial Keratoplasty Tissue Preparation.. Cornea. 2020. DOI: 10.1097/ico.0000000000002338.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.