m+Medelevator.RU
← Поиск публикаций
Cornea · 2020

Endothelial Cell Density Changes in the Corneal Center Versus Paracentral Areas After Descemet Membrane Endothelial Keratoplasty.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Musayeva Aytan, Livny Eitan, Dragnea Diana C, Ham Lisanne, Vasiliauskaitė Indrė, Ní Dhubhghaill Sorcha, van Dijk Korine, Oellerich Silke, Melles Gerrit R J

Аннотация

PURPOSE: To analyze whether endothelial cell density (ECD) differs between central and paracentral areas after Descemet membrane endothelial keratoplasty (DMEK) and to identify the locations of the highest and lowest ECD.

METHODS: In this retrospective cohort study, central and paracentral ECDs of 30 eyes of 30 patients who underwent DMEK for Fuchs endothelial corneal dystrophy were evaluated. Central, superonasal, superotemporal, and inferior specular microscopic images were analyzed at 1, 3, 6, 9, and 12 months after DMEK. Changes in ECD by location and over time and changes in location for the highest and lowest ECD were evaluated.

RESULTS: When compared with the preoperative donor ECD, the central ECD decreased by 32 (±11)% at 12 months postoperatively. ECD decline between 1 and 12 months postoperatively in the central, inferior, superonasal, and superotemporal location were 7%, 12%, 16%, and 13%, respectively (P < 0.0001 for all locations). Mean ECD was the highest in the center between the 3- to 12-month follow-up, whereas mean ECD was the lowest in the paracentral superonasal area at all time points (P < 0.001). Mean ECD of the highest and lowest density locations differed at all follow-up time points (P < 0.003).

CONCLUSIONS: Postoperative ECD was not found to be uniform across the graft. Contrary to the density distribution in the normal endothelium, paracentral area ECDs were found to be consistently lower than in the central area. These differences were most prominent in the superonasal area and persisted 12 months postoperatively. Central ECD after DMEK might, thus, not represent an accurate proxy for cell density of the entire graft.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты