HPB : the official journal of the International Hepato Pancreato Biliary Association · 2023
Liver splitting during normothermic machine perfusion: a novel method to combine the advantages of both in-situ and ex-vivo techniques.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lau Ngee-Soon, Ly Mark, Dennis Claude, Ewenson Kasper, Ly Hayden, Huang Joanna L, Cabanes-Creus Marti, Chanda Sumon, Wang Chuanmin, Lisowski Leszek, Liu Ken, Kench James, McCaughan Geoffrey, Crawford Michael, Pulitano Carlo
Аннотация
BACKGROUND: Split liver transplantation permits the transplant of two recipients using a single donor liver. Liver splitting can be performed using the ex-vivo technique (more convenient), or the in-situ technique (shorter cold ischaemic time). We aimed to develop a technique for liver splitting during normothermic machine perfusion which combines the advantages of both techniques and permits graft assessment prior to transplant.
METHODS: Human livers declined for transplantation were perfused at 36 °C using a modified-commercial perfusion machine. We developed a six-step method to split whole livers into left lateral segment grafts and extended right grafts. Both partial livers were then perfused on separate machines for individual assessment.
RESULTS: Using our technique, 10 whole livers were successfully split during normothermic perfusion resulting in 20 partial grafts. Apart from a single graft which failed due to a technical error, all grafts survived for 24-h after splitting. Survival was demonstrated by lactate clearance, bile production and synthesis of coagulation factors.
CONCLUSIONS: Liver splitting during normothermic machine perfusion has the potential to revolutionise split liver transplantation. We describe a novel technique that reliably achieves two grafts from a single donor liver. This raises the possibility of semi-elective transplantation, and sophisticated graft assessment prior to implant.
METHODS: Human livers declined for transplantation were perfused at 36 °C using a modified-commercial perfusion machine. We developed a six-step method to split whole livers into left lateral segment grafts and extended right grafts. Both partial livers were then perfused on separate machines for individual assessment.
RESULTS: Using our technique, 10 whole livers were successfully split during normothermic perfusion resulting in 20 partial grafts. Apart from a single graft which failed due to a technical error, all grafts survived for 24-h after splitting. Survival was demonstrated by lactate clearance, bile production and synthesis of coagulation factors.
CONCLUSIONS: Liver splitting during normothermic machine perfusion has the potential to revolutionise split liver transplantation. We describe a novel technique that reliably achieves two grafts from a single donor liver. This raises the possibility of semi-elective transplantation, and sophisticated graft assessment prior to implant.