MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cjca.2019.03.028

Медицинская библиотека · The Canadian journal of cardiology · 2019

Outcome of Patients Undergoing Transcatheter Implantation of Aortic Valve With Previous Mitral Valve Prosthesis (OPTIMAL) Study.

Baldetti Luca, Giannini Francesco, Van Mieghem Nicolas, El Faquir Nahid, Tchétché Didier, De Biase Chiara, Petronio Anna Sonia, Giannini Cristina, Tarantini Giuseppe, Fraccaro Chiara, Finkelstein Ariel, Segev Amit, Barbash Israel, Bruschi Giuseppe, Tamburino Corrado, Barbanti Marco, Lim Scott, Kuntjoro Ivandito, Abdel-Wahab Mohamed, Colombo Antonio, Latib Azeem

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is the gold standard for severe valvular aortic stenosis in patients at high/prohibitive surgical risk. This procedure has also been used in patients with previous mitral valve (MV) prostheses, with contrasting outcomes reported. The aim of this study is to describe procedural and early outcomes of patients with previous MV prostheses undergoing TAVR.

METHODS

This is a retrospective registry of 154 patients with previous MV prostheses who underwent TAVR across high-volume medical centres at a mean of 11.7 ± 8.4 years after mitral surgery.

RESULTS

Mean mitroaortic distance at computed tomography was 9.7 ± 4.8 mm. Procedural success was achieved in 150 (97.4%) patients, with reduction of aortic gradients (42.6 ± 14.2 to 10.0 ± 7.0 mm Hg; P < 0.001). Device success was achieved in 133 (86.3%) patients. MV prosthesis interference by the TAVR device was observed in 2 patients; in both, the mitroaortic distance was <5 mm, with 1 complicated by TAVR prosthesis embolization. Periprocedural complications included 4 (2.6%) cerebrovascular accidents, 10 (6.6%) major vascular complications, 22 (14.4%) severe bleedings, 1 (0.7%) myocardial infarction, and 5 (3.2%) in-hospital deaths (all cases cardiovascular or procedure related). At a median follow-up of 13.5 (interquartile range 1.0 to 36.0) months, 26 (16.9%) deaths occurred; 15 (9.7%) were cardiac related. Late fatal mitral prosthesis thromboses occurred in 2 patients. We recorded a case of fatal hemorrhagic stroke; hospital readmission was observed in 25 (16.2%) patients due to worsening heart failure.

CONCLUSIONS

TAVR in patients with previous mitral prostheses appears to be safe and feasible, with good hemodynamic results at 30-day and at longer-term follow-up.

Для цитирования: Baldetti Luca, Giannini Francesco, Van Mieghem Nicolas, El Faquir Nahid, Tchétché Didier, De Biase Chiara, Petronio Anna Sonia, Giannini Cristina, Tarantini Giuseppe, Fraccaro Chiara, Finkelstein Ariel, Segev Amit, Barbash Israel, Bruschi Giuseppe, Tamburino Corrado, Barbanti Marco, Lim Scott, Kuntjoro Ivandito, Abdel-Wahab Mohamed, Colombo Antonio, Latib Azeem. Outcome of Patients Undergoing Transcatheter Implantation of Aortic Valve With Previous Mitral Valve Prosthesis (OPTIMAL) Study.. The Canadian journal of cardiology. 2019. DOI: 10.1016/j.cjca.2019.03.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.