m+Medelevator.RU
← Поиск публикаций
The Journal of thoracic and cardiovascular surgery · 2019

Evaluation of a hybrid small caliber vascular graft in a rabbit model.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fang Qin, Gu Tianxiang, Fan Jun, Zhang Yuanming, Wang Yongchao, Zhao Ye, Zhao Pan

Аннотация

OBJECTIVE: A hybrid small-caliber artificial vascular graft based on bilayer porcine small intestinal submucosa (SIS) with curdlan and dipyridamole mixture film serving as the so-called sandwich filler was developed for biological performance evaluation. We evaluated the performance of the graft and filler.

METHODS: SIS was coated with heparin by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide. Curdlan acted as the carrier of dipyridamole. Three types of graft tubes (2 mm internal diameter and 20 mm in length) were manufactured: bilayer SIS with 10% curdlan + 10% dipyridamole mixture film (SCD), bilayer SIS with 10% curdlan film (SC), and monolayer SIS (S). The remodeling characteristics of the grafts were evaluated by implanting them as bypass in rabbit carotid arteries for 2 and 3 months. Each group contained 16 rabbits, and 16 nonsurgical rabbits served as the control group.

RESULTS: Eight rabbits of each group, including the graft occluded group, were killed at 2 months and the others were killed at 3 months. Follow-up showed that all 8 grafts in SCD group were patent at 2 months. Six of 16 grafts in the SC group and 5 of 16 grafts in the S group were occluded at 2 months. One of 8 SCD grafts were occluded at 3 months and the patent showed a confluent endothelium without intimal hyperplasia. The neointima layer was composed of circumferentially aligned vascular smooth muscle cells. At 3 months, SC and S group grafts showed incomplete endothelialization and varying degrees of mural thrombus, accompanied by occlusion in the SC group (3 of 8) and S group (2 of 8).

CONCLUSIONS: The novel hybrid small caliber artificial vascular graft exhibited an improvement in revascularization resulting in high patency rate.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты