Comparative analysis of whole blood clot viscoelastic properties via thromboelastography and plasma fibrin clot characteristics.
СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Natorska Joanna, Kopytek Magdalena, Gołąb Aleksandra, Waśniowska Anna, Konieczyńska Małgorzata, Undas Anetta, Ząbczyk Michał
Аннотация
BACKGROUND: Thromboelastography (TEG) is used in various clinical settings to assess clot formation, strength, and lysis. It is unknown whether TEG measures correspond to plasma fibrin clot characteristics.
METHODS: In 90 individuals free of cardiovascular disease (51 [56.7%] women, aged 49.3 ± 5.2 years, body-mass index [BMI], 26 [23.8-29.3] kg/m2) we assessed whole blood clot parameters (reaction [R] and clot formation [K] time, clot growth kinetics [angle], maximum amplitude [MA], and clot lysis [LY30]) using the TEG 6s analyzer (Haemonetics, Boston, US), plasma clot permeability (Ks), and clot lysis time (CLT) using three assays: (1) by Pieters (CLT-2018), (2) by Lisman (CLT), and (3) by Carter (Lys50).
RESULTS: There were associations of Ks with K time (R = 0.29, p = 0.0053), angle (R = -0.31, p = 0.0033), and MA (R = -0.47, p < 0.0001), while CLT tended to correlate with LY30. In women compared to men Ks was 8.4% lower corresponding to 7% higher MA (both p < 0.001). In obese (n = 19, 21.1%) vs. non-obese individuals angle was 5% larger (p = 0.029) but BMI did not correlate with TEG measures. TEG parameters and fibrin clot properties were unaffected by smoking, hypertension or hyperlipidemia. More efficient fibrinolysis (LY30 > 2.6%) was detected in 15 (16.7%) individuals who had also shorter CLT-2018 and CLT (both p < 0.05). Hypofibrinolysis (CLT-2018 > 300 min; n = 8, 8.9%) was detected only using CLT with no differences in TEG indices or Lys50.
CONCLUSIONS: TEG and plasma fibrin clot properties are complementary methods for assessing hemostasis, however, fibrin clot properties better reflect the impact of clinical risk factors on fibrinogen modification.
METHODS: In 90 individuals free of cardiovascular disease (51 [56.7%] women, aged 49.3 ± 5.2 years, body-mass index [BMI], 26 [23.8-29.3] kg/m2) we assessed whole blood clot parameters (reaction [R] and clot formation [K] time, clot growth kinetics [angle], maximum amplitude [MA], and clot lysis [LY30]) using the TEG 6s analyzer (Haemonetics, Boston, US), plasma clot permeability (Ks), and clot lysis time (CLT) using three assays: (1) by Pieters (CLT-2018), (2) by Lisman (CLT), and (3) by Carter (Lys50).
RESULTS: There were associations of Ks with K time (R = 0.29, p = 0.0053), angle (R = -0.31, p = 0.0033), and MA (R = -0.47, p < 0.0001), while CLT tended to correlate with LY30. In women compared to men Ks was 8.4% lower corresponding to 7% higher MA (both p < 0.001). In obese (n = 19, 21.1%) vs. non-obese individuals angle was 5% larger (p = 0.029) but BMI did not correlate with TEG measures. TEG parameters and fibrin clot properties were unaffected by smoking, hypertension or hyperlipidemia. More efficient fibrinolysis (LY30 > 2.6%) was detected in 15 (16.7%) individuals who had also shorter CLT-2018 and CLT (both p < 0.05). Hypofibrinolysis (CLT-2018 > 300 min; n = 8, 8.9%) was detected only using CLT with no differences in TEG indices or Lys50.
CONCLUSIONS: TEG and plasma fibrin clot properties are complementary methods for assessing hemostasis, however, fibrin clot properties better reflect the impact of clinical risk factors on fibrinogen modification.