Development and application of an electronic synoptic report for reporting and management of low-dose computed tomography lung cancer screening examination.

Tremblay Alain, Ezer Nicole, Burrowes Paul, MacGregor John Henry, Lee Andrew, Armstrong Gavin A, Pereira Raoul, Bristow Michael, Taylor Jana L, MacEachern Paul, Taghizadeh Niloofar, Koetzler Rommy, Bedard Eric

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Interpretation of Low Dose CT scans and protocol driven management of findings is a key aspect of lung cancer screening program performance. Reliable and reproducible methods are needed to communicate radiologists' interpretation to the screening program or clinicians driving management decision.

METHODS

We performed an audit of a subset of dictated reports from the PANCAN study to assess for omissions. We developed an electronic synoptic reporting tool for radiologists embedded in a clinical documentation system software. The tool was then used for reporting as part of the Alberta Lung Cancer Screening Study and McGill University Health Centre Pilot Lung Cancer Screening Program.

RESULTS

Fifty reports were audited for completeness. At least one omission was noted in 30 (70%) of reports, with a major omission (missing lobe, size, type of nodule in report or actionable incidental finding in recommendation section of report) in 24 (48%). Details of the reporting template and functionality such as automated nodule cancer risk assessment, Lung-RADS category assignment, auto-generated narrative type report as well as personalize participant results letter is provided. A description of the system's performance in its application in 2815 CT reports is then summarized.

CONCLUSIONS

We found that narrative type radiologist reports for lung cancer screening CT examinations frequently lacked specific discrete data elements required for management. We demonstrate the successful implementation of a radiology synoptic reporting system for use in lung cancer screening, and the use of this information to drive program management and communications.

Для цитирования: Tremblay Alain, Ezer Nicole, Burrowes Paul, MacGregor John Henry, Lee Andrew, Armstrong Gavin A, Pereira Raoul, Bristow Michael, Taylor Jana L, MacEachern Paul, Taghizadeh Niloofar, Koetzler Rommy, Bedard Eric. Development and application of an electronic synoptic report for reporting and management of low-dose computed tomography lung cancer screening examination.. BMC medical imaging. 2022. DOI: 10.1186/s12880-022-00837-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.