MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-011-9460-2

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2011

High-resolution imaging of human atherosclerotic carotid plaques with micro 18F-FDG PET scanning exploring plaque vulnerability.

Masteling Marleen G, Zeebregts Clark J, Tio René A, Breek Jan-Cees, Tietge Uwe J F, de Boer Jan Freark, Glaudemans Andor W J M, Dierckx Rudi A J O, Boersma Hendrikus H, Slart Riemer H J A

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: FDG-PET can be used to identify vulnerable plaques in atherosclerotic disease. Clinical FDG-PET camera systems are restricted in terms of resolution for the visualization of detailed inflammation patterns in smaller vascular structures. The aim of the study is to evaluate the possible added value of a high-resolution microPET system in excised carotid plaques using FDG.

METHODS AND

RESULTS

In this study, 17 patients with planned carotid endarterectomy were included. Excised plaques were incubated in FDG and subsequently imaged with microPET. Macrophage presence in plaques was evaluated semi-quantitatively by immunohistochemistry. Plaque calcification was assessed additionally with CT and correlated to FDG uptake. Finally, FDG uptake and macrophage infiltration were compared with patient symptomatology. Heterogeneous distributions and variable intensities of FDG uptake were found within the plaques. A positive correlation between the distribution of macrophages and the FDG uptake (r = 0.68, P < .01) was found. A negative correlation was found between areas of calcifications and FDG uptake (r = -0.84, P < .001). Ratio FDG(max) values as well as degree of CD68 accumulation were significantly higher in CVA patients compared with TIA or amaurosis fugax patients (P < .05) and CVA patients compared with asymptomatic patients (P < .05).

CONCLUSION

This ex vivo study demonstrates that excised carotid plaques can be visualized in detail using FDG microPET. Enhancement of clinical PET/CT resolution for similar imaging results in patients is needed.

Для цитирования: Masteling Marleen G, Zeebregts Clark J, Tio René A, Breek Jan-Cees, Tietge Uwe J F, de Boer Jan Freark, Glaudemans Andor W J M, Dierckx Rudi A J O, Boersma Hendrikus H, Slart Riemer H J A. High-resolution imaging of human atherosclerotic carotid plaques with micro 18F-FDG PET scanning exploring plaque vulnerability.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2011. DOI: 10.1007/s12350-011-9460-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.