MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiochem.2009.09.028

Медицинская библиотека · Clinical biochemistry · 2009

Soluble urokinase-type plasminogen activator receptor forms in plasma as markers of atherosclerotic plaque vulnerability.

Olson Fredrik J, Thurison Tine, Ryndel Mikael, Høyer-Hansen Gunilla, Fagerberg Björn

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

: To test if circulating forms of the soluble urokinase-type plasminogen activator receptor (suPAR) are potential biomarkers of plaque vulnerability.

DESIGN AND

METHODS

: Plasma concentrations of suPAR(I-III), suPAR(II-III) and uPAR(I) were measured by time-resolved fluorescence immunoassays in Caucasian patients operated for symptomatic carotid atherosclerosis (n=255). Local suPAR release from plaques into the circulation was assessed in plasma passing retrogradely over the plaque in the carotid artery, collected during surgery (n=7).

RESULTS

: The suPAR(I-III) (P=0.03) and suPAR(II-III) (P=0.006) concentrations were higher after ischemic strokes and transient ischemic attacks, i.e., clinical subgroups associated with poorer prognosis and a less stable plaque phenotype, than after amaurosis fugax. Slightly elevated suPAR(I-III) levels were found in plasma from the carotid lesion. However, refuting the hypothesis, the concentrations of the suPAR forms were not higher in patients with short intervals between clinical event and blood sampling compared with those with long intervals. Age, inflammatory markers and diabetes were confounding factors independently associated with suPAR forms.

CONCLUSION

: Circulating suPAR forms are probably not useful biomarkers of atherosclerotic plaque vulnerability.

Для цитирования: Olson Fredrik J, Thurison Tine, Ryndel Mikael, Høyer-Hansen Gunilla, Fagerberg Björn. Soluble urokinase-type plasminogen activator receptor forms in plasma as markers of atherosclerotic plaque vulnerability.. Clinical biochemistry. 2009. DOI: 10.1016/j.clinbiochem.2009.09.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.