MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2009.07.018

Медицинская библиотека · Thrombosis research · 2009

Coagulation activation and ultrasound characteristics in patients with carotid artery disease.

Kölbel Tilo, Goncalves Isabel, Dias Nuno, Strandberg Karin, Acosta Stefan, Gottsäter Anders

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Elevated levels of markers for thrombin activation are associated with plaque echogenicity and degree of stenosis in patients with carotid artery stenosis. The Activated Protein C-Protein C Inhibitor (APC-PCI) complex reflects activation of the Protein C system and is a measure of thrombin generation. The aim of the present study was to examine APC-PCI complex in patients undergoing thrombendartherectomy for carotid artery stenosis, and to relate the findings to clinical characteristics and plaque morphology as determined by ultrasound.

MATERIALS AND

METHODS

Blood was obtained from 125 patients (39 female, median age 71 years) with carotid artery stenosis admitted from September 2005 to May 2007. The APC-PCI complex was measured using a sandwich immunofluorometric method and compared to an age- and sex-matched healthy control-group. Clinical and demographic characteristics, routine laboratory markers and ultrasound characteristics were analysed using univariate and multivariate analysis.

RESULTS

APC-PCI complex concentration was significantly increased in patients with carotid artery stenosis (median 0.21 microg/L; 10th to 90th percentile 0.15-0.36) compared to a healthy control-group (0.19 microg/L; 0.11-0.31; P=.009). There was no significant difference in APC-PCI-values between asymptomatic (n=48) and symptomatic (n=77) patients with carotid artery stenosis (0.22 vs. 0.20 microg/L; p=0.626). Patients with minor stroke (n=31) had a higher median APC-PCI-concentration (0.27 microg/L; 0.15-0.63) than patients with amaurosis fugax (0.19 microg/L; 0.15-0.36) or transient ischemic attack (0.21 microg/L; 0.12-0.36) (p=0.016). No association was found between APC-PCI-values and the degrees of carotid artery stenosis or the time from the latest neurological symptoms to blood sampling. Patients with echolucent plaques had significantly lower APC-PCI concentrations (0.20 microg/L; 0.14-0.35 vs. 0.24 microg/L; 0.15-0.60; p=0.043), according to the Gray-Weale classification.

CONCLUSIONS

Patients with carotid artery disease exhibit increased concentrations of APC-PCI compared to a healthy control-group, particularly those patients with echogenic plaques, who have significantly higher APC-PCI levels than patients with echolucent plaques.

Для цитирования: Kölbel Tilo, Goncalves Isabel, Dias Nuno, Strandberg Karin, Acosta Stefan, Gottsäter Anders. Coagulation activation and ultrasound characteristics in patients with carotid artery disease.. Thrombosis research. 2009. DOI: 10.1016/j.thromres.2009.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.