MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mayocpiqo.2021.08.006

Медицинская библиотека · Mayo Clinic proceedings. Innovations, quality & outcomes · 2021

Evaluation of Changing Vena Cava Filter Use and Inpatient Hospital Mortality from 2016-2019: A Single-Institution Quality Improvement Project.

Augustine Matthew R, Knavel Koepsel Erica M, Peterson Lisa G, Rupkalvis Laurie, Comstock Ann, McPhail Ian, McBane Robert D, Bjarnason Haraldur, Houghton Damon E

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the changing trends of vena cava filter (VCF) insertion and determine whether changes in VCF use affected inpatient mortality.

PATIENTS AND

METHODS

A quality improvement project at Mayo Clinic, Rochester, Minnesota, tracks the type and reason for VCF insertions from January 1, 2016, through December 31, 2019, to facilitate appropriate retrieval. The rate of VCF insertions was compared with inpatient mortality rates, normalized for patient volumes using the number of hospital inpatient discharges.

RESULTS

A total of 698 VCFs were placed in 695 patients: 2016 (n=243), 2017 (n=156), 2018 (n=156), and 2019 (n=120). The rate of VCF insertions (per 1000 inpatient discharges) was 4.02 in 2016, 2.91 in 2017, 2.54 in 2018, and 1.93 in 2019. Mean ± SD age at placement was 62±16.4 years and 59.2% (413/698) were men. Most VCFs were retrievable (85.1%; 594/698) and were placed for treatment (78.4%; 547/698) indications (acute venous thromboembolism within 3 months). The rate of VCF insertions was compared with the inpatient mortality rate (per 100 inpatient discharges) and remained stable (1.83 in 2016, 1.79 in 2017, 1.83 in 2018, and 1.76 in 2019) despite the significant decline in VCF use.

CONCLUSION

Data from this quality improvement study demonstrate a reduction of more than 50% in the use of VCFs from 2016 through 2019 at a large academic hospital. These changes are difficult to attribute to any single change in clinical use and there was no appreciable increase in the inpatient hospital mortality rate associated with this decrease in VCF filter use.

Для цитирования: Augustine Matthew R, Knavel Koepsel Erica M, Peterson Lisa G, Rupkalvis Laurie, Comstock Ann, McPhail Ian, McBane Robert D, Bjarnason Haraldur, Houghton Damon E. Evaluation of Changing Vena Cava Filter Use and Inpatient Hospital Mortality from 2016-2019: A Single-Institution Quality Improvement Project.. Mayo Clinic proceedings. Innovations, quality & outcomes. 2021. DOI: 10.1016/j.mayocpiqo.2021.08.006.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.