Safety and efficacy of leadless pacemakers: A systematic review and meta-analysis.

Soleimani Hamidreza, Dastjerdi Parham, Hosseini Mohammadi Negin Sadat, Najdaghi Soroush, Shayesteh Hedieh, Narimani Davani Delaram, Yarmohammadi Hirad, Eslami Masoud, Mollazadeh Reza

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Leadless pacemakers (LPs) are emerging as a transformative alternative to traditional transvenous pacemakers (TVPs) for managing brady-arrhythmias. Unlike TVPs, LPs eliminate the need for leads and subcutaneous generator pockets, addressing complications.

OBJECTIVE

This meta-analysis aimed to evaluate the safety and efficacy of LPs, including Micra (Medtronic) and Aveir VR (Abbott) devices, in comparison to TVPs.

METHOD: A systematic review and meta-analysis were conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Overall, 55 studies involving 286,349 patients met the inclusion criteria.

RESULTS

LPs demonstrated significantly lower risks of pneumothorax (relative risk [RR], 0.29; P = .019, event rate: 0.14% [LP] vs 0.93% [TVP], number needed to treat [NNT] = 128) and lead dislodgement (RR, 0.21; 95% confidence interval, 0.16-0.28; P < .0001, event rate: 0.36% [LP] vs 2.29% [TVP], NNT = 52) compared with TVPs, with negligible infection rates. However, LPs were associated with higher risks of cardiac tamponade (RR, 2.36; P = .007, event rate: 0.84% [LP] vs 0.46% [TVP], number needed to harm [NNH] = 265) and access site complications (RR, 2.82; P < .0001, event rate: 2.03% [LP] vs 0.62% [TVP], NNH = 71).

CONCLUSION

LPs offer distinct advantages over TVPs, including reduced risks of certain complications and improved procedural efficiency.

Для цитирования: Soleimani Hamidreza, Dastjerdi Parham, Hosseini Mohammadi Negin Sadat, Najdaghi Soroush, Shayesteh Hedieh, Narimani Davani Delaram, Yarmohammadi Hirad, Eslami Masoud, Mollazadeh Reza. Safety and efficacy of leadless pacemakers: A systematic review and meta-analysis.. Heart rhythm O2. 2025. DOI: 10.1016/j.hroo.2025.08.044.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.