MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.13563

Медицинская библиотека · Contact dermatitis · 2020

Optoacoustic mesoscopy shows potential to increase accuracy of allergy patch testing.

Hindelang Benedikt, Aguirre Juan, Berezhnoi Andrei, He Hailong, Eyerich Kilian, Ntziachristos Vasilis, Biedermann Tilo, Darsow Ulf

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Differentiation between irritant and allergic skin reactions in epicutaneous patch testing is based largely on subjective clinical criteria, with the risk of high intraobserver and interobserver variability. Novel dermatological imaging using optoacoustic mesoscopy allows quantitative three-dimensional assessment of microvascular biomarkers.

OBJECTIVES

We investigated the potential of optoacoustic imaging to improve the precision of patch test evaluation.

METHODS

Sixty-nine test reactions and 48 healthy skin sections in 52 patients with suspected type IV allergy were examined using raster-scan optoacoustic mesoscopy.

RESULTS

We identified biomarkers from the optoacoustic images. Allergic reactions were associated with higher fragmentation of skin vasculature than irritant reactions (19.5 ± 9.7 vs 14.3 ± 3.7 fragments/100 pixels2 ; P < .05), as well as lower ratio of low- to high-frequency acoustic signals (1.6 ± 0.5 vs 2.0 ± 0.6, P < .05). Allergic reactions graded "++" showed higher vessel fragmentation than reactions graded "+" (25.4 ± 13.2 vs 17.1 ± 6.5 fragments/100 pixels2 ; P < .05). A linear model combining the biomarkers fragmentation and frequency ratio could differentiate allergic from irritant test reactions with an area under the receiving operator characteristic curve of 0.80 (95% confidence interval 0.64-0.91), reaching a sensitivity of 81% and specificity of 63%.

CONCLUSIONS

Optoacoustic mesoscopy shows potential to help in differentiating between allergic and irritant test reactions based on novel biomarkers that may reflect vasodilation, vessel tortuosity, and edema.

Для цитирования: Hindelang Benedikt, Aguirre Juan, Berezhnoi Andrei, He Hailong, Eyerich Kilian, Ntziachristos Vasilis, Biedermann Tilo, Darsow Ulf. Optoacoustic mesoscopy shows potential to increase accuracy of allergy patch testing.. Contact dermatitis. 2020. DOI: 10.1111/cod.13563.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.