MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0b013e318064e8d4

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2007

Positional vertigo and cochlear implantation.

Viccaro Marika, Mancini Patrizia, La Gamma Raffaella, De Seta Elio, Covelli Edoardo, Filipo Roberto

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To identify patients developing positional vertigo after cochlear implantation.

STUDY

DESIGN

Prospective study on a cohort of patients undergoing cochlear implantation.

SETTING

Academic tertiary referral center.

PATIENTS: The study included 70 consecutive patients who underwent vestibular evaluation before and after cochlear implantation.

INTERVENTION: Medical record review.

MAIN OUTCOME MEASURE: Recorded vestibular symptoms after cochlear implantation. Patients with positional vertigo were considered case subjects, whereas those without vestibular symptoms were considered case controls.

RESULTS

Benign paroxysmal positional vertigo (BPPV) occurred in 8 patients (on the cochlear implant [CI] side in 7 patients, and in the other ear in 1). One patient had BPPV of the lateral semicircular canal on the implanted side, and 7 patients had BPPV of the posterior semicircular canal (on the same CI side in 6 patients, and on the opposite side in 1), which were detected and presented during the last examination. In 5 patients, the onset of symptoms varied from 7 to 130 days after implant activation; in 2 patients, the onset occurred before activation.

CONCLUSION

Three different mechanisms are proposed for the occurrence of BPPV in patients with CI. The first focuses on the fall of bone dust particles into the cochlea during cochleostomy. In the second, the vibration caused by drilling the cochlea would be sufficient to dislodge otoconia into the labyrinth. The third hypothesis suggests dislodging of an otolith because of the electric stimulation. In our patients, conservative approaches have been used with a minimal invasive cochleostomy and without perilymph suction. Thus, the vibratory trauma affecting the cochlea during cochleostomy seems to play a fundamental role in the development of paroxysmal vertigo in patients with implant.

Для цитирования: Viccaro Marika, Mancini Patrizia, La Gamma Raffaella, De Seta Elio, Covelli Edoardo, Filipo Roberto. Positional vertigo and cochlear implantation.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2007. DOI: 10.1097/mao.0b013e318064e8d4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.