Lung Volume Dependence and Repeatability of Hyperpolarized 129Xe MRI Gas Uptake Metrics in Healthy Volunteers and Participants with COPD.

Garrison William J, Qing Kun, He Mu, Zhao Li, Tustison Nicholas J, Patrie James T, Mata Jaime F, Shim Y Michael, Ropp Alan M, Altes Talissa A, Mugler John P, Miller G Wilson

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the effect of lung volume on measured values and repeatability of xenon 129 (129Xe) gas uptake metrics in healthy volunteers and participants with chronic obstructive pulmonary disease (COPD).

MATERIALS AND

METHODS

This Health Insurance Portability and Accountability Act-compliant prospective study included data (March 2014-December 2015) from 49 participants (19 with COPD [mean age, 67 years ± 9 (SD)]; nine women]; 25 older healthy volunteers [mean age, 59 years ± 10; 20 women]; and five young healthy women [mean age, 23 years ± 3]). Thirty-two participants underwent repeated 129Xe and same-breath-hold proton MRI at residual volume plus one-third forced vital capacity (RV+FVC/3), with 29 also undergoing one examination at total lung capacity (TLC). The remaining 17 participants underwent imaging at TLC, RV+FVC/3, and residual volume (RV). Signal ratios between membrane, red blood cell (RBC), and gas-phase compartments were calculated using hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (ie, IDEAL). Repeatability was assessed using coefficient of variation and intraclass correlation coefficient, and volume relationships were assessed using Spearman correlation and Wilcoxon rank sum tests.

RESULTS

Gas uptake metrics were repeatable at RV+FVC/3 (intraclass correlation coefficient = 0.88 for membrane/gas; 0.71 for RBC/gas, and 0.88 for RBC/membrane). Relative ratio changes were highly correlated with relative volume changes for membrane/gas (r = -0.97) and RBC/gas (r = -0.93). Membrane/gas and RBC/gas measured at RV+FVC/3 were significantly lower in the COPD group than the corresponding healthy group (P ≤ .001). However, these differences lessened upon correction for individual volume differences (P = .23 for membrane/gas; P = .09 for RBC/gas).

CONCLUSION

Dissolved-phase 129Xe MRI-derived gas uptake metrics were repeatable but highly dependent on lung volume during measurement.Keywords: Blood-Air Barrier, MRI, Chronic Obstructive Pulmonary Disease, Pulmonary Gas Exchange, Xenon Supplemental material is available for this article © RSNA, 2023.

Для цитирования: Garrison William J, Qing Kun, He Mu, Zhao Li, Tustison Nicholas J, Patrie James T, Mata Jaime F, Shim Y Michael, Ropp Alan M, Altes Talissa A, Mugler John P, Miller G Wilson. Lung Volume Dependence and Repeatability of Hyperpolarized 129Xe MRI Gas Uptake Metrics in Healthy Volunteers and Participants with COPD.. Radiology. Cardiothoracic imaging. 2023. DOI: 10.1148/ryct.220096.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.