BACKGROUND

It is known that tachygastria is associated with gastric hypomotility and retrograde gastric electrical stimulation (RGES) delays gastric emptying and is proposed for treating obesity. The aim was to investigate the effects and mechanisms of RGES on postprandial antral contraction in dogs.

METHODS

Seven dogs were implanted with a gastric cannula and three pairs of gastric serosal electrodes. Antral contractions and gastric myoelectrical activity were recorded immediately after a solid meal, with or without RGES, or with GES on the corpus, or with RGES under administration of propranolol. The stimulus was composed of long pulses with a tachygastrial frequency.

RESULTS

(i) GES at the tachygastrial frequency impaired gastric myoelectrical activity and induced tachygastria (anovaP<0.05). (ii) GES at the tachygastrial frequency suppressed antral contractions (anovaP<0.01) and the effect was stronger with retrograde stimulation than forward stimulation (P<0.05). (iii) GES-induced tachygastria was correlated with antral hypomotility (r=-0.60, P=0.01). (iv) Propranolol and phentolamine abolished GES-induced tachygastria and antral hypomotility.

CONCLUSIONS

Long-pulse RGES at a tachygastrial frequency suppresses postprandial antral contractions, which is attributed to an induction of tachygastria via the alpha- and beta-adrenergic pathway.

Для цитирования: Ouyang H, Xing J, Chen J D Z. Tachygastria induced by gastric electrical stimulation is mediated via alpha- and beta-adrenergic pathway and inhibits antral motility in dogs.. Neurogastroenterology and motility. 2005. DOI: 10.1111/j.1365-2982.2005.00696.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.