MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2009.03.027

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2009

Prevalence of serum antibodies to TORCH among women before pregnancy or in the early period of pregnancy in Beijing.

Li Zhiyan, Yan Cuiling, Liu Ping, Yan Rong, Feng Zhenru

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The primary infection of Toxoplasma gondii (TOX), rubella virus (RV), cytomegalovirus (CMV), or herpes simplex virus (HSV), abbreviated as TORCH, remains a major problem in the pregnant women in China today.

METHODS

We analyzed the performance of a novel chemiluminesent immunoassay (CLIA) for anti-TORCH IgM and IgG detection then analyzed the prevalence of TORCH infection among 4692 women at childbearing age in Beijing, China.

RESULTS

The functional sensitivity of detecting anti-TOX IgM, anti-RV IgM, anti-CMV IgM and anti-HSV (types 1 and 2) IgM were 1.4, 3.2, 1.0 AU/ml and 0.5 index, respectively. The within-assay and the total CVs were both <10%, and recoveries of these assays ranged from 90-110%. High concentration of hemoglobin, lipids and bilirubin in sample did not affect the results. The infective rate of TORCH was 17.2%, with the highest positive rate of anti-HSV IgM. Within anti-TORCH IgG, anti-CMV IgG had the highest infective rate, 92.5%.

CONCLUSIONS

The infective rate of TORCH was fairly high among women before pregnancy or in the early period of pregnancy in Beijing. Entirely new approaches to prevention and treatment of congenital TORCH infection are necessary.

Для цитирования: Li Zhiyan, Yan Cuiling, Liu Ping, Yan Rong, Feng Zhenru. Prevalence of serum antibodies to TORCH among women before pregnancy or in the early period of pregnancy in Beijing.. Clinica chimica acta; international journal of clinical chemistry. 2009. DOI: 10.1016/j.cca.2009.03.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.