MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diabres.2023.110239

Медицинская библиотека · Diabetes research and clinical practice · 2023

Effect of sodium-glucose co-transporter 2 inhibitors on plasma potassium: A meta-analysis.

Charlwood Chloe, Chudasama Jenika, Darling Andrea L, Logan Ellis Hugh, Whyte Martin B

МетаанализСтатьяПеревод пока не подготовлен

Аннотация

AIMS: There has been uncertainty whether SGLT2 inhibition predisposes to hyperkalaemia or is protective from it. We therefore performed a meta-analysis to assess effects of SGLT2 inhibition on serum-potassium and hyperkalaemia-events in T2DM.

METHODS

MEDLINE and PubMed databases were searched for 'hyperkalaemia' or 'potassium', with SGLT2 inhibitors in T2DM, to 31st December 2020. Randomised controlled trials, with potassium or hyperkalaemia as primary or secondary outcomes, were included. Cochran's Q test and I2 statistic assessed statistical heterogeneity. Meta-analyses were performed using Cochrane-RevMan with two outcomes: i) Odds ratio (OR) of hyperkalaemia-events between SGLT2 inhibitor and placebo (fixed-effects), ii) Mean difference (MD) in change from baseline potassium between SGLT2 inhibitor and placebo (random-effects).

RESULTS

Of 1724 identified publications, nine were included in the meta-analysis (n = 3 hyperkalaemia event; n = 5 serum-potassium; n = 1 reported both outcomes). Pooled OR for hyperkalaemia-events for SGLT2 inhibitor vs placebo was 0.72 [95% confidence interval (CI) 0.61 to 0.85, P < 0.001], I2 of 9%. The pooled MD in serum-potassium concentration with SGLT2 inhibitor vs placebo was -0.04 mmol/L [95% CI -0.08 to 0.00 mmol/L; P = 0.04], I2 of 89%.

CONCLUSIONS

Use of SGLT2 inhibitors in T2DM reduced odds of inducing hyperkalaemia but had a minimal effect of lowering serum potassium.

Для цитирования: Charlwood Chloe, Chudasama Jenika, Darling Andrea L, Logan Ellis Hugh, Whyte Martin B. Effect of sodium-glucose co-transporter 2 inhibitors on plasma potassium: A meta-analysis.. Diabetes research and clinical practice. 2023. DOI: 10.1016/j.diabres.2023.110239.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.