MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm.2004.148

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2004

Quality assessment in cytogenetic and molecular genetic testing: the experience of the Italian Project on Standardisation and Quality Assurance.

Taruscio Domenica, Falbo Vincenzo, Floridia Giovanna, Salvatore Marco, Pescucci Chiara, Cantafora Alfredo, Marongiu Cesarina, Baroncini Anna, Calzolari Elisa, Cao Antonio, Castaldo Giuseppe, Bricarelli Franca Dagna, Guanti Ginevra, Nitsch Lucio, Pignatti Pier Franco, Rosatelli Cristina, Salvatore Francesco, Zuffardi Orsetta

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The first Italian national trial of external quality assessment in genetic testing was organised within the framework of the "Italian National Project for Standardisation and Quality Assurance of Genetic Tests". Sixty-eight Public Health Service laboratories volunteered for the trial, which involved molecular genetic tests (cystic fibrosis, beta-thalassaemia, familial adenomatous polyposis coli and fragile-X syndrome) and cytogenetic tests (prenatal and postnatal, the latter included cancer cytogenetics). The response rate was high (88.2%). The level of analytical accuracy was good, i.e., the percentage of laboratories that correctly genotyped all samples was 89.3% for cystic fibrosis, 90.9% for beta-thalassaemia, 100% for familial adenomatous polyposis coli (despite two laboratories did not complete the analysis because the amount of DNA was considered insufficient), and 90.5% for fragile-X syndrome. Written reports differed widely and were judged "inadequate" in over 50% of cases. Most laboratories from the present study already have experience in previous European external quality assessments for at least one genetic test; this can explain the higher analytical accuracy in the Italian external quality assessment with respect to quality control programmes in other countries. Collaborative networks are strongly suggested to improve the quality of the reports.

Для цитирования: Taruscio Domenica, Falbo Vincenzo, Floridia Giovanna, Salvatore Marco, Pescucci Chiara, Cantafora Alfredo, Marongiu Cesarina, Baroncini Anna, Calzolari Elisa, Cao Antonio, Castaldo Giuseppe, Bricarelli Franca Dagna, Guanti Ginevra, Nitsch Lucio, Pignatti Pier Franco, Rosatelli Cristina, Salvatore Francesco, Zuffardi Orsetta. Quality assessment in cytogenetic and molecular genetic testing: the experience of the Italian Project on Standardisation and Quality Assurance.. Clinical chemistry and laboratory medicine. 2004. DOI: 10.1515/cclm.2004.148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.